Events - Actions; Event Setup - Bentel Security KYO 320 Installation Manual

Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

N.
3415
Memo message present
3416
K-NET module missing
3417
Lan Link missing
3418
IP receiver missing
Tabella 7 Special events for KYO320.

Events - Actions

From the Programming menu:
PROGRAMMING
Configuration
1. Using A or B, select Event -> Action:
PROGRAMMING
Event
à Action
2. Press ENTER:
Event à
Action
Event n.
0001
3. Enter the Event ID number, then press ENTER.
+
NOTE: The Event ID numbers can be found in the
No. column of the Event tables. For events that re-
gard system elements such as: Zones, Partitions,
Outputs, Codes, Keypads, Keys/Cards and Rea-
ders, you must add the ID number of the object to
the Event ID number shown in the Event No. co-
lumn. EXAMPLE: The Event ID number of Bur-
glar alarm on partition 1 is 0753 (i.e. 0752 +
partition 1 = 0753), whereas, the Event ID number
of Burglar alarm on partition 6 is 0758 (i.e. 0752
+ partition 6 = 0758).
Event
n.
0001
Output
____
4. Enter the ID number of the Output associated with
the selected event (enter all zeros for NO Output), then
using A or B, select Dig.Com.On.
Events n.
0001
Dig.Com.
On ___
5. Enter the ID number of the Digital Communicator ac-
tion the Control panel must perform when the selected
event occurs (enter all zeros for NO action), then using
A or B, select Dig.Com.Off.
Events n.
0001
Dig.Com.
Off___
6. Enter the ID number of the Digital Communicator ac-
tion the Control panel must perform when the selected
KYO320
EVENTO
PROGRAM PANEL
event ends (enter all zeros for NO action), then using A
or B, select Dialler On.
Event
n.
0001
Dialler On
___
7. Enter the ID number of the Dialler action which the
Control panel must perform when the selected event
occurs (enter all zeros for NO action), then using A or
B, select Dialler Off.
Event n.
0001
Dialler Off
___
8. Enter the ID number of the Dialler action which the
Control panel must perform when the selected event
ends (enter all zeros for NO action), then press ENTER
to go back to step 3.

Event setup

The Event setup option will allow you to program the
Event Types to be stored in the Logger and/or printed
in real time (refer to"Logger – Setting up events" under
"Programming").
PROGRAMMING
Configuration
1. Using A or B, select the Event setup option.
PROGRAMMING
Event setup
2. Press ENTER:
Event setup 001
Zone Alarm
3. Using A or B, select the required Event Type, or en-
ter the Event Type ID number (3 digits, see NOTE),
then press ENTER.
+
NOTE: The Event Type ID numbers can be found
in the No. column of the Event Type tables.
For Event Types with 2 digit ID numbers, you must
enter zero (0) followed by the 2 digit ID number.
Zone Alarm
Log enabled
x
4. Using A or B, select the Log enabled option (refer
to "") or Printer enabled option (refer to "Printout").
Press ON or OFF to enable or disable the option con-
cerned, then press ENTER and go back to step 3.
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents