Recommended maximum distance limitations

The maximum recommended length of each type of cable connection you may use
with PortServer II are shown below.
Note: Although PortServer II may operate adequately if you exceed a given limita-
tion, performance may be degraded.

Ethernet

10BaseT: Maximum distance of 330 ft (100 M) at a transmission rate of 10
megabits/second (10 Mbps).
10Base2: Maximum distance of 610 ft (185 M) at a transmission rate of 10
megabits/second (10 Mbps).

EIA RS-232 serial ports

Maximum distance depends on the data rate and the type of cable:
Table 1
Data Rate (Baud)
2400
4800
9600
19200
38400
57600
115200
V.24 cable
If you are connecting to a Frame Relay service, you require a fully V.24-compatible
cable. Distance limitations are the same as for serial cables.
Page 30
RS232 Serial Port Specifications
Installation
Distance (ft)
200
100
50
25
12.5
6.3
3.2
Distance (M)
60
30
15
7.5
3.8
1.9
0.9