Note: factory configured only for correct input voltage range (specified at time of purchase)
Single Phase or Three-Phase (Single-Phase not available for 5 hp)
50 or 60 Hz.
Tolerance:
Input voltage +10%/-15% maximum
Input frequency range 48 Hz to 62 Hz
Motor Req:
Commercially available motor supplied by the manufacturer of the pump controller
See Section 14 for motor selection requirements
Motor Distance: Maximum motor to controller distance is 100 feet (30.5 meters)
For distances greater than 25 feet (7.6 meters) see motor information, next page
Consult factory for distances greater than 100 feet (30.5 meters)
Keypad:
Mounted to MPC VECTOR main enclosure, can be made remote from the enclosure, maximum of 1000 feet
Display:
Backlit 2 line extended temperature 16 character LCD
Enclosure:
NEMA 4X and IP56 ratings and open chassis panel mount option available
Altitude:
3300 Ft (1000 M) above sea level (derate 5% HP for each additional 3300 feet)
Humidity:
0-90% (non-condensing)
o
o
Temperature:
0
C (32
F) Minimum operating temperature
o
o
40
C (104
Earth Leakage
Current:
Size Earth Leakage Circuit Breakers (ELCB) to a detection level of 30 mA or greater