Idex Pulsafeeder MPC Vector Installation, Operation & Maintenance Manual page 46

Universal control for pulsa and eclipse. suitable for any gear, reciprocating or positive displacement pumps.
Table of Contents

Advertisement

4. Press ENTER to edit the high speed ("HI SPEED" where the default = 1800 RPM) and flow rate calibration
point.
5. Using the UP/DOWN/ENTER keys enter the calibration speed and flow points.
6. Press the ENTER key to accept the calibration flow rate and proceed to the low speed calibration point.
7. Press ENTER to edit the low speed (default=180 RPM) and flow rate calibration point.
8. Using the UP/DOWN/ENTER keys enter the calibration speed and flow points.
9. Press the ENTER key to accept the calibration flow rate and save the two point calibration.
10. At this point, the system will check the dry calibration values, and if the values are acceptable will complete the
calibration.
8.1.1.2
Open Loop Wet Flow Calibration
The Open Loop Wet Flow Calibration routine requires the user to run the pump and record the corresponding flow
at two known pump speeds.
Before proceeding, ensure the following:
Then proceed with the following steps from the handheld remote:
1. Press the MENU key to access the Calibration Menu.
2. Press the ENTER key to access Pump Flow Calibration screen.
P U M P F L O W
D R Y C A L
H I S P E E D : 1 8 0 0 R P M
F L O W :
L O W S P E E D : 1 8 0 R P M
F L O W :
P U M P F L O W
C A L I B R A T E D
That it is safe to run the pump and dispense liquid into the system.
That the pump is fully primed with the product.
That the calibration column has enough fluid for the dispensing time to prevent a run dry
scenario.
That you are prepared to record the volume and time interval for 2 draw downs.
- M E N U -
C A L I B R A T I O N
C A L I B R A T I O N
P U M P F L O W
2 5 . 0 0 G P H
2 . 5 0 G P H
40