Idex Pulsafeeder MPC Vector Installation, Operation & Maintenance Manual page 74

Universal control for pulsa and eclipse. suitable for any gear, reciprocating or positive displacement pumps.
Table of Contents

Advertisement

NON-FATAL ERRORS: The pump and controller can still be run while these conditions exist.
The Red LED will flash and the error will flash on the screen. The Red LED and error message
will cease once the error condition has been corrected.
PUMP FLOW
OUT OF RANGE
CONSULT factory
Error = ####
USER NOTIFICATIONS: These are errors in setup or calibration. They will display on the
screen for several seconds. They can be corrected by properly completing the procedure
involved.
Cannot access
With motor on
Current delta
Out of range
No remote
Control
For unlisted or numbered error codes, consult the factory for assistance.
The flow set point has not been attained for duration of 60
seconds. (Closed Loop Operation Only)
Self Clearing - Pump Motor will continue to run, showing a
pump flow out of range error message. Once actual flow
meets the flow set point the warning will clear.
Unidentified error, record error number and consult factory
User is trying to change a setting that cannot be changed
while the pump is running. Press motor on/off key to turn
motor off.
Not enough difference between high and low signals during
an analog input signal calibration (min 3 mA)
User is trying to activate the AUTO mode, but the analog
input is not active or remote on/off is not configured for the
controller.