Idex Pulsafeeder MPC Vector Installation, Operation & Maintenance Manual page 37

Universal control for pulsa and eclipse. suitable for any gear, reciprocating or positive displacement pumps.
Table of Contents

Advertisement

The pump has internal software protections and validations which prevent the motor from exceeding 1800 RPM
(approximate). Example: If the pump can only achieve 2.5GPM at 1800 RPM for your system configuration and the
flow rate is set to 10GPM, the motor will spin at 1800 RPM and produce 2.5GPM.
What is Max Speed?
Max Speed is the maximum speed that the motor can spin, according to the manufacturer. This is largely unused by
the MPC Vector at the moment and will not affect operations. It is recommended that this value is kept at 1800
RPM.
Setting Max Flow (example shown with GPM units)
1) Begin at the main screen displaying the current flow/speed set point
2) Press the MENU key to access the menus.
3) Press the UP or DOWN arrow keys until you get to System Setup.
4) Press the ENTER key to access System Setup Menus.
5) Press the UP key until you see the Information setup option.
6) Press the ENTER key to access the Information screens.
P
7)
ress the UP or DOWN arrow keys until you see Max flow and Speed displayed.
8) Press the Enter key to allow Max Flow to be edited. A blinking cursor will appear
9) Press the UP or DOWN arrow keys to manipulate the flow rate until you reach your max flow.
P
10)
ress the ENTER key to accept the new Max Flow rate. Note that the blinking cursor has moved to the Max
Speed location.
S E T P T
0 . 0 0 G P M
F L O W
0 . 0 0 G P M
- M E N U -
C A L I B R A T I O N
- M E N U -
S Y S T E M S E T U P
S Y S T E M S E T U P
S T A T U S
S Y S T E M S E T U P
I N F O R M A T I O N
P U L S A F E E D E R , I N C
F W : 1 . 0 4 / 1 . 0 4
M A X :
M A X :
M A X :
M A X :
M A X :
M A X :
31
6 . 0 0 G P M
1 8 0 0 R P M
6 . 0 0 G P M
1 8 0 0 R P M
8 . 5 0 G P M
1 8 0 0 R P M

Advertisement