Idex Pulsafeeder MPC Vector Installation, Operation & Maintenance Manual page 56

Universal control for pulsa and eclipse. suitable for any gear, reciprocating or positive displacement pumps.
Table of Contents

Advertisement

8.1.3.2
"DRY" Set point Input Calibration (keypad only, no signal present)
1. The starting display will be:
2. Press the MENU key
3. Press the ENTER key
4. Press the UP arrow key twice, to access the analog input calibration
5. Press the ENTER key
6. Press the UP or DOWN key
7. Press the ENTER key to access the DRY Pump Flow Calibration routine for ANALOG Flow Meters. A blinking
cursor will show you that you are adjusting the Current (mA).
8. Press the UP and/or DOWN keys to adjust the Current set point.
9. Press the ENTER key to accept this setpoint. The Cursor will now blink on the second line, indicating that the
flow rate at 20.0 mA is the active field. Press the UP and/or DOWN keys to adjust the Flow setpoint.
10. Press the ENTER key to access the MIN setpoint values. The cursor will blink on the top line indicating
that the Current setpoint may be adjusted.
11. Press the UP and/or DOWN arrow keys to adjust the Max Current setpoint.
S E T P T
X X . X X X
F L O W
X X . X X X
- M E N U -
C A L I B R A T I O N
C A L I B R A T I O N
P U M P F L O W
C A L I B R A T I O N
A N A L O G I N P U T
A N A L O G I N P U T
W E T C A L
A N A L O G I N P U T
D R Y C A L
M A X S E T P T
F L O W :
0 . 0 0 G P M
M A X S E T P T
F L O W :
0 . 0 0 G P M
M I N S E T P T
F L O W :
0 . 0 0 G P M
M A X S E T P T 1 6 . 0 M A
F L O W :
4 . 0 0 G P M
M A X S E T P T 2 0 . 0 M A
F L O W :
4 . 0 0 G P M
50
0 . 0 M A
2 0 . 0 M A
4 . 0 M A