Ff520 Fish Finder Setup; Aux Connector Table - Standard Horizon CPV550 Owner's Manual

Gps chart plotter with vhf fm marine transceiver
Table of Contents

Advertisement

2.7

FF520 FISH FINDER SETUP

When a FF520 is connected to the GPS Chart Plotter:
a. The Gray and white wires cannot be used to connect to external NMEA devices.
b. Port 2 of the NMEA in/out Communication setup menu must be changed so the GPS
Chart Plotter can communicate with the FF520.
1. From the Chart page, press [MENU]. Move the ShuttlePoint knob to highlight SETUP
MENU and press [ENT].
2. Move the ShuttlePoint knob to highlight ADVANCED SETUP and press the [ENT] key.
3. Move the ShuttlePoint knob to highlight IN/OUT CONNECTIONS and press the [ENT]
key.
4. Move the ShuttlePoint knob to highlight PORT2 INPUT and press the [ENT] key.
5. Move the ShuttlePoint knob up/down to select FF520 and press the [ENT] key. Press
[CLR] or move the ShuttlePoint knob to the left until the Chart page is shown.
2.7.0

AUX Connector Table

Pin
Wire Color Description
1
Black
NMEA Common
2
Red
---
3
Green
NMEA Common
4
Blue
---
5
Brown
---
6
Gray
NMEA Input Port 4
7
White
NMEA Output Port 4
8
Yellow
---
Page 22
Figure 2.7 IN/OUT CONNECTION menu
Connection Example
Common for NMEA devices
No Connection
Common for NMEA devices
No Connection
No Connection
Conncect to output of NMEA device
Conncect to intput of NMEA device
No Connection
Additional Information
Default is NMEA0183
Default is NMEA0183 with GLL. RMB, RMC, and XTE sentences
CPV550