Tci Analog Input Checks - Komatsu 930E-2 Shop Manual

Dump truck w/ cummins qsk60 engine
Table of Contents

Advertisement

TCI Analog Input Checks:

On the TCI PTU:
¤ Move cursor to "Normal Operation" {enter}
¤ Cursor to "TCI Real Time Data" {enter}
1. Verify analog values and functions highlighted on the PTU are similar to the examples below:
Note: Actual values shown
in illustrations will vary from
those displayed on truck
being serviced:
2. Press {enter} to display "TCI SERIAL LINK DATA" screen shown below:
3. Press {enter} to display "TCI ANALOG INPUT CHANNELS" screen below:
E03015 3/01
AC Drive System Electrical Checkout Procedure
(Release 17 Software)
E3-13