In Case Of Fire; Attach Indicator Light Assy; Remove Test Module - Komatsu 930E-2 Shop Manual

Dump truck w/ cummins qsk60 engine
Table of Contents

Advertisement

FIGURE 2.3-20. ATTACH INDICATOR LIGHT ASSY.
(Test Module)
If test module light does not illuminate, refer to
"Troubleshooting" covered in this section.
9. Proceed to the end of the last length of detection
wire and remove the jumper assembly. Put origi-
nal plugged blank connector back on detection
wire. Test module light should immediately go out.
If light does not go out, refer to "Troubleshooting"
covered in this section.
FIGURE 2.3-21. REMOVE TEST MODULE
M02003
Ansul "Checkfire" Electric Detection and Actuation System
10. Remove the test kit from the system by discon-
necting the squib connector from the test module
(Figure 2.3-21).
Failure to remove jumper assembly will cause sys-
tem discharge when squib is installed into Electric
Detection and Actuation System.
11. Remove squib from actuator body and check that
it has not been fired. Reinstall squib and wrench
tighten firmly.
12. Reinstall squib connector to squib and firmly
tighten by hand.
13. Pull ring pin on Electric Detection and Actuation
System actuator and push pin several times to
insure smooth movement. Reinstall ring pin and
attach lead wire seal.
14. Install actuation cartridge back into lower actuator
body and tighten firmly by hand.

IN CASE OF FIRE

Procedure to follow during and after a fire. In the event
of a fire, the following steps should be taken:
1. Turn the machine "Off".
2. Manually activate fire suppression system, if pos-
sible.
3. Move away from the machine taking a hand port-
able extinguisher along if you can.
4. Stand-by with a portable fire extinguisher to put out
any possible re- ignition of the fire after the fire
suppression system is expended.
Explanation of the above steps.
1. If you leave the machine running, it may add fuel
to the fire or restart the fire with sparks.
2. May help put fire down more quickly.
3. By leaving the immediate fire area, you protect
yourself from windblown flames, explosions or
other dangers created by the fire.
4. Having a hand portable fire extinguisher is advised
because remaining heat may cause part of the fire
to re-ignite after the fire suppression system has
discharged. Depending on the heat that remains,
this may occur a number of times, so remain alert
until the equipment cools and you are assured
that re-ignition is not likely.
M2.3-7