Regulator Bypass Test; Test Meter Hookup - Komatsu 930E-2 Shop Manual

Dump truck w/ cummins qsk60 engine
Table of Contents

Advertisement

FIGURE 13-2. TEST METER HOOKUP
1. Alternator Under Test
2. 0 to 400 AMP Ammeter
3. 0 to 40 VDC Voltmeter
4. Alternator "B+" Terminal
5. Alternator Ground Terminal
6. Truck Batteries

Regulator Bypass Test

If the test procedure outlined on the previous page
indicates low current output and low voltage out-
put, perform the following test to determine if the
voltage regulator is defective or if the alternator is
defective.
1. Disconnect alternator/regulator harness plug (3,
Figure 13-3).
2. Momentarily touch the "F-" connector pin on the
alternator connector to ground.
3. Observe meter readings:
If voltage or amperage rises, the alternator is
OK. The regulator is defective and should be
replaced.
If grounding the harness male pin has no effect,
the alternator is defective and should be re-
placed.
M13002 2/99
FIGURE 13-3. REGULATOR BYPASS TEST
1. Alternator Control Unit
2. "R" Terminal (Relay)
3. "E" Terminal (Energize)
4. Alternator "B+" Terminal
5. Alternator/Voltage Regulator Harness Plug
24VDC Electric Supply System
with 220 Amp. Niehoff Alternator
M13-5

Advertisement

Table of Contents
loading