Pedal Percentages And Meter Calibration; Meter Calibration Procedure; Retard Pedal; Retard Lever - Komatsu 930E-2 Shop Manual

Dump truck w/ cummins qsk60 engine
Table of Contents

Advertisement

Pedal Percentages and Meter Calibration

The following procedures are used to calibrate the
retarder and accelerator pedals, retarder lever, and the
hydraulic brake temperature and propel system tem-
perature gauges and the speedometer for the soft-
ware. If any of the above components require
replacement during truck servicing or troubleshooting
procedures, the new or rebuilt component must be
recalibrated using the applicable procedure before the
truck is returned to service.
1. Connect the serial communication cable from the
PTU to the PSC port, behind the center console
on the driver's side.
2. Turn keyswitch and Control power Switch ON.
3. Enter the following on the PTU:
¤ c:\>ACNMENU {enter}
¤ Highlight "PTU TCI & PSC" {enter}
¤ Type your name {enter}
¤ Type your password {enter}
¤ Cursor to "Normal Operation" {enter}
¤ Cursor to "View/Set PSC Analog Outputs" {enter}
A: Retard Pedal:
¤ Cursor to the box in the "#" column on channel
one {enter}
¤ Type in: 359 {enter}
1. Parameter name will be rpinhi_ail5.
Record the parameter value with the retard
pedal fully released. (typical value; 1.50
volts).
Record the parameter value with the retard
pedal fully depressed. (typical value; 9.50
volts).
B: Retard Lever:
¤ Cursor to the box in the "#" column on channel
two {enter}
¤ Type in: 344 {enter}
1. Parameter name will be retlever_ail4.
Record the parameter value with the lever
up (typical value; 0.0 volts).
Record the parameter value with the lever
down (typical value; 8.75 volts).
E3-22
AC Drive System Electrical Checkout Procedure
(Release 17 Software)

Meter Calibration Procedure

1. Connect the serial communication cable from the
PTU to the TCI port, behind the center console,
on the passenger side.
2. Turn ON the Key Switch and the Control Power
Switch.
3. On the PTU, enter the following:
¤ c:\>ACNMENU {enter}
¤ Highlight "PTU TCI & PSC" {enter}
¤ Type your name {enter}
¤ Type your password {enter}
4. Turn park brake switch ON and turn Rest switch
OFF.
C: Hydraulic Brake Fluid Temperature Meter:
¤ Cursor to "Engine Stopped Tasks" {enter}
¤ Cursor to "Temporary Meter Calibration". {enter}
¤ Cursor to the box to the right of "Type a Test Hy-
draulic brake Fluid Temperature" {enter}
¤ Type in: 120 {enter}
5. Hydraulic Brake Fluid Temperature meter should
move to a position near the line separating green
and red.
¤ Move the cursor to the "Increment\Decrement"
boxes and press {enter} to position the meter
pointer on the line between the green and red
sections.
6. When at the desired meter position, record the
value shown in the Gauge Scale box.
D: Propulsion System Temperature Meter:
¤ Cursor to the box to the right of "Type a Test Pro-
pulsion System Temperature" {enter}
¤ Type in: 60 {enter}
7. Propulsion System Temperature meter should
move to a position near the line separating green
and yellow.
¤ Move the cursor to the "Increment\Decrement"
boxes and press {enter} to position the meter
pointer between the green and yellow sections.
8. When at the desired meter position, record the
value that is in the Gauge Scale box.
3/01 E03015