Appendix D: Replacing System Components; Replacing The Primary Unit - SolarEdge SE66.6KUS Installation Manual

Three phase inverter with synergy technology
Hide thumbs Also See for SE66.6KUS:
Table of Contents

Advertisement

Appendix D: Replacing System Components

Appendix D: Replacing System Components
This appendix details replacement procedures for the SolarEdge system components. 
NOTE
If you are permanently disassembling the installation or part of it, make sure to use the disposal
methods dictated by local regulations.

Replacing the Primary Unit

 1.  Turn OFF the Inverter ON/OFF switch, and wait until the green LED is blinking , indicating that the DC 
voltage is safe (<50V), or wait five minutes before continuing to the next step.
WARNING!
If you cannot see Primary Unit LEDs or you cannot connect to the Primary Unit, or if the red LED
light is on indicating a malfunction , wait five minutes for the input capacitors of the inverter to
discharge.
Si vous ne pouvez pas voir les LED de l'unité principale ou si vous ne pouvez pas vous connecter à
l'unité principale, ou si le voyant LED rouge s'allume, attendez cinq minutes que les condensateurs
d'entrée de l'onduleur se déchargent.
 2.  Disconnect the AC to the inverter by turning OFF the circuit breakers on the distribution panel.
 3.  For a 3-unit inverter first disconnect and remove the Secondary Unit on the right.
 4.  Open the Primary Unit cover:
a. Release the   s ix Allen screws of the cover.
b. Tilt the top of the cover towards you.
c. Slide the cover down and remove it. 
CAUTION!
When removing the cover, make sure not to damage internal components. SolarEdge will not be
held responsible for any components damaged as a result of incautious cover removal.
Lors du retrait du couvercle, assurez-vous de ne pas endommager les composants internes.
SolarEdge ne peut être tenue pour responsable des composants endommagés à la suite d'une
imprudence dans le retrait du couvercle.
 5.  Disconnect all DC, AC wires and the communication connectors   f rom the Primary Unit. 
78
-Three Phase Inverter with Synergy Technology Installation MAN-01-00402-1.4
Figure 51: Primary Unit interface

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se100kusSe43.2kus

Table of Contents