SolarEdge SE66.6KUS Installation Manual page 64

Three phase inverter with synergy technology
Hide thumbs Also See for SE66.6KUS:
Table of Contents

Advertisement

 4.  Push the cable into the cut opening of the rubber fitting.
CAT5/5E STP cables have eight wires (four twisted pairs), as shown in the diagram below. Wire colors may 
differ from one cable to another. You can use either wiring standard, as long as both sides of the cable 
have the same pin-out and color-coding.
RJ45 Pin #
1
2
3
4
5
6
7
8
1 The connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends on the switch
capabilities.
-Three Phase Inverter with Synergy Technology Installation MAN-01-00402-1.4
Figure 38: Communication gland and rubber fitting
Wire Color
T568B
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Chapter 6: Setting Up Communication
   
1
T568A
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
10Base-T Signal
100Base-TX Signal
Transmit+
Transmit-
Receive+
Reserved
Reserved
Received-
Reserved
Reserved
63