Message
Description
Erasing Memory
Handset has determined that a download
should occur and is erasing the current
software from memory.
Far End TCP Close
The handset has lost communication with the
PBX.
Files Too Big
Handset software download files are
incorrect or corrupted
Flash Config Error
Handset internal configuration is corrupt.
Forced Redirect
The PBX has told the handset to re-register
with another PBX.
Get Button Defs
The Handset is attempting to get definitions
from the PBX of how the user-programmable
keys are currently programmed.
Initializing ...
The handset is performing power on
initialization
Internal Err. # #
The handset has detected a fault from which
it cannot recover.
Invalid Redirect
The PBX has told the handset to re-attempt
registration with another PBX. The reason
code in the redirect message is invalid.
Multiple GW Res
More than one NetLink SVP Server has
responded
Multiple SVP Reg
y...y = SVP IP address
yyy.yyy.yyy.yyy
Handset received responses from multiple
SVP Servers; displays IP address of one
responding SVP Server
Must Upgrade SW!
Handset software is incompatible with
hardware.
PN: 72-1084-02-E.doc
Configuration and Administration—NetLink e340/i640 Wireless Telephone
Mitel Networks 3300 and SX-200 ICP and 5220 IP Phone emulation
Action
None. When the progress bar fills the
display line the erase operation is
complete.
Do not turn the handset off during this
operation.
No action necessary. After about 20
seconds, the handset will re-initialize and
reconnect to either the same PBX or to
another PBX if it has been instructed to do
so or the first PBX fails to respond.
Download new software from the
SpectraLink site per
Maintenance
Perform "Restore Defaults" operation via
administrator menus [or reprogram with
Configuration Cradle]
No action necessary.
No action necessary.
None. This is informational only.
Record the error code so it can be
reported.
Turn the handset off then on again.
If error persists, try registering a different
handset to this telephone port.
If error still persists, contact SpectraLink
Technical Support and report the error.
No action necessary.
Caused by two or more handsets sharing
the same IP address. Assign unique IP
addresses to each phone.
This can happen if the handset has been
re-configured to use a different SVP server
and then powered-up before the previous
server has had time to determine that the
handset is no longer connected to it. The
problem should go away after about 30
seconds.
Download new software from the
SpectraLink site per
Maintenance
Software
.
Software
.