Mitsubishi Electric Melsec QJ71LP21 Reference Manual page 316

Q corresponding melsecnet/h network system
Hide thumbs Also See for Melsec QJ71LP21:
Table of Contents

Advertisement

7
APPLICATION FUNCTIONS
Setting data
Setting data
1
Network No. of the target station (1 to 239, 254)
"Jn"/Jn
254: The network specified in Valid module during other station access
Start I/O number of the host station's network module
"Un"/Un
(00 to FE
Channel used by host station (1 to 8)
Specify the channel used by the host station.
n1
Specify the channel used by host station that is the same as the one used for the RSTOP
instruction.
Target station No.
Specify the station No. of the target station.
1) Station No. specification
1 to 64: Station No.
2) Group specification
n2
3
81
H
3) All stations specification
FF
H
When a group is specified, set the group No. of the target station with the network
parameters from GX Developer.
Target station's CPU type
Specify the CPU module on the station to be accessed.
n3
When the instruction is executed with control system CPU (03D0
CPU (03D1
execution may fail. (Error code: 4244
If the instruction has failed with the above error, execute it again.
Mode
Specify options for the operation mode and clear mode.
1) Operation mode
Specify whether to forcibly execute remote RUN or not.
1
: No forced execution
H
3
: Forced execution
H
The forced execution is a function that forces a station, which has stopped by remote
STOP, to RUN remotely from another station.
n4
2) Clear mode
Specify the CPU module device status for the case of remote RUN.
0
: Do not clear (Note that the local devices are cleared.)
H
1
: Clear (excluding the latch range)
H
2
: Clear (including the latch range)
H
Clear mode allows specification of the CPU module device clear (initialization) process at
the start of CPU module operation activated by remote RUN.
The CPU module will perform the specified clear processing, and then it will run according
to the setting that can be confirmed by [PLC parameters] - [PLC file] - [Initial Device value]
in GX Developer.
The host station's device that is turned on for one scan upon completion of the instruction
(D1)+1 also turns on if the instruction execution is failed, and the error code is stored in
(D)
the SW0031 to SW003F.
(For the error code, refer to Section 8.3.)
7 - 92
: The higher two digits of the 3-digit I/O number)
H
to A0
: All stations of a group (No.1 to 32)
H
: All stations of the target network No. (Except the host station)
Setting value
Control CPU (The access target is the same as when "03FF
0000
4
H
is specified.)
03D0
4
Control system CPU
H
03D1
4
Standby system CPU
H
03D2
4
System A CPU
H
03D3
4
System B CPU
H
 Control CPU (single CPU system)
03E0
5
H
 Multiple CPU system No.1
03E1
5
Multiple CPU system No.2
H
03E2
5
Multiple CPU system No.3
H
03E3
5
Multiple CPU system No.4
H
03FF
Control CPU
H
) specified, if system switching occurs at the target station, the instruction
H
, 4248
H
b15
to
0
Description
Description
) or standby system
H
)
H
b8 b7to b4 b3 to b0
2)
1)
MELSEC-Q
Setting side
2
String/Binary 16 bits
"
H
User
System
Data type
Binary 16 bits
Bit
7 - 92