APPLICATION FUNCTIONS
Setting data
Setting data
1
Network No. of the target station (1 to 239, 254)
"Jn"/Jn
254: The network specified in Valid module during other station access
Start I/O number of the host station's network module
"Un"/Un
(00 to FE
Channel used by host station (1 to 8)
n1
Specify the channel used by the host station.
n2
Target station No. (1 to 64)
Target station's CPU type
Specify the CPU module on the station to be accessed.
n3
When the instruction is executed with control system CPU (03D0
CPU (03D1
execution may fail. (Error code: 4244
If the instruction has failed with the above error, execute it again.
Start device of the host station, in which clock data are stored
(D1)
(Refer to the clock data table.)
The host station's device that is turned on for one scan upon completion of the instruction
(D2)+1 also turns on if the instruction execution is failed, and the error code is stored in
(D2)
the SW0031 to SW003F.
(For the error code, refer to Section 8.3.)
1: Local devices and file registers for each program cannot be used as devices in setting data.
2: The setting side is as shown below.
User
: It is data the user sets in the sequence program before execution of a link dedicated instruction.
System: The programmable controller CPU stores the execution result of the link dedicated instruction.
3: The CPU type can be specified when the host station is a network module of which function version is either D or later or the following
Network module: Serial number (first five digits) "10101" or later
(The CPU module cannot be specified in the case other than the above. Only access to the control CPU is available.)
Clock data
Device
Item
(D1)+0
(D1)+1
Clock data
(D1)+2
(D1)+3
7 - 101
: The higher two digits of the 3-digit I/O number)
H
Setting value
Control CPU (The access target is the same as when "03FF
0000
3
H
is specified.)
03D0
3
Control system CPU
H
03D1
3
Standby system CPU
H
03D2
3
System A CPU
H
03D3
3
System B CPU
H
 Control CPU (single CPU system)
03E0
H
 Multiple CPU system No.1
03E1
Multiple CPU system No.2
H
03E2
Multiple CPU system No.3
H
03E3
Multiple CPU system No.4
H
03FF
Control CPU
H
) specified, if system switching occurs at the target station, the instruction
H
, 4248
H
Clock data that have been read are stored as BCD codes. (all set by the system)
The range available for 4-digit year reading is 1980 to 2079.
Description
Description
) or standby system
H
)
H
b15
to
(D1)
0
Year (00
to 99
), Last 2 digits
H
H
(D1)
1
Day (01
to 31
H
Minute (00
to 59
(D1)
2
H
(D1)
3
Year (19
to 20
), First 2 digits
H
H
Setting side
"
H
User
System
Setting data
to
b8
b7
Month (01
to 12
H
)
Hour (00
to 23
H
H
Second (00
to 59
)
H
H
Day of week (00
H
00
(Sun.) to 06
H
MELSEC-Q
2
Data type
String/Binary 16 bits
Binary 16 bits
Device name
Bit
b0
)
H
)
H
)
H
to 06
)
H
(Sat.)
H
7 - 101