Mitsubishi Electric Melsec QJ71LP21 Reference Manual page 467

Q corresponding melsecnet/h network system
Hide thumbs Also See for Melsec QJ71LP21:
Table of Contents

Advertisement

APPENDICES
No.
Name
2
11
SW0080
(128)/
SW0081
CPU operation status of
(129)/
each station (1)
SW0082
(130)/
SW0083
(131)
2
SW0084
(132)/
SW0085
CPU RUN status of each
(133)/
station
SW0086
(134)/
SW0087
(135)
2
10
SW0088
(136)/
SW0089
CPU operation status of
(137)/
each station (2)
SW008A
(138)/
SW008B
(139)
2: Valid only when the SB0047 is off. When it turns on (error), the last data are retained.
10: Minor errors are the type of errors that do not affect the CPU operation.
11: Serious errors are the type of errors that stop the CPU operation.
Fatal errors are also the type of errors that stop the CPU operation.
App - 28
Table 4 Link special register (SW) list (continued)
Description
Stores each station's CPU status (including the host).
Valid only for stations registered as normal in the SW0070 to
SW0073.
0: Normal (including the stations with the maximum station
number and smaller numbers as well as reserved stations)
1: Serious/fatal error
b15 b14 b13 b12
SW0080
16
15
14
13
SW0081
32
31
30
29
SW0082
48
47
46
45
SW0083
64
63
62
61
Stores the CPU RUN status of each station (including the host).
The standby-system Q4ARCPU stores the key switch status at
normal state.
Valid only for stations registered as normal in the SW0070 to
SW0073.
0: RUN or STEP RUN (including the stations with the
maximum station number and smaller numbers as well as
reserved stations)
1: STOP, PAUSE, ERROR
b15 b14 b13 b12
SW0084
16
15
14
13
SW0085
32
31
30
29
SW0086
48
47
46
45
SW0087
64
63
62
61
Stores each station's CPU status (including the host).
Valid only for stations registered as normal in the SW0070 to
SW0073.
0: Normal (including the stations with the maximum station
number and smaller numbers as well as reserved stations)
1: Minor error
b15 b14 b13 b12
SW0088
16
15
14
13
SW0089
32
31
30
29
SW008A
48
47
46
45
SW008B
64
63
62
61
to
b4
b3
b2
b1
b0
to
5
4
3
2
1
to
21
20
19
18
17
34
to
37
36
35
33
to
53
52
51
50
49
Numbers 1 to 64 in the above table
indicate the station numbers.
to
b4
b3
b2
b1
b0
to
5
4
3
2
1
to
21
20
19
18
17
34
to
37
36
35
33
to
53
52
51
50
49
Numbers 1 to 64 in the above table
indicate the station numbers.
to
b4
b3
b2
b1
b0
to
5
4
3
2
1
21
20
19
18
17
to
to
37
36
35
34
33
to
53
52
51
50
49
Numbers 1 to 64 in the above table
indicate the station numbers.
[Availability column] Loop: optical loop, Bus: coaxial/twisted bus
MELSEC-Q
Use permitted/prohibited
Remote
Control
Normal
master
station
station
station
Loop
Bus
Loop
Bus
Loop
: Available,
Remote I/O
station
Bus
Loop
Bus
: Not available
App - 28