Mitsubishi Electric Melsec QJ71LP21 Reference Manual page 280

Q corresponding melsecnet/h network system
Hide thumbs Also See for Melsec QJ71LP21:
Table of Contents

Advertisement

7
APPLICATION FUNCTIONS
Control data
Device
Item
Error completion
(S1)+0
type
(S1)+1
Completion status
Channel used by
(S1)+2
host station
Target station's
(S1)+3
CPU type
Target station
(S1)+4
network No.
(S1)+5
Target station No.
(S1)+6
(Use prohibited)
(S1)+7
Number of resends
5: The setting side is as shown below.
User
: It is data the user sets in the sequence program before execution of a link dedicated instruction.
System: The programmable controller CPU stores the execution result of the link dedicated instruction.
6: The CPU type can be specified when the host station is a network module of which function version is either D or later or the following.
• Network module: Serial number (first five digits) "10101" or later
(The CPU module cannot be specified in the case other than the above. Only access to the control CPU is available.)
7: The CPU type can be specified when the QCPUs and network modules of the host station or target station are the following versions.
• Network module: Serial number (first five digits) "06092" or later
• QCPU: Serial number (first five digits) "06092" or later
(The CPU module cannot be specified in the case other than the above. Only access to the control CPU is available.)
7 - 56
b15
to
0
1) Error completion type (bit 7)
Specify the clock data setup status for error completion.
0: Clock data at the time of error completion is not set in the area starting from (S1)+11.
1: Clock data at the time of error completion is set in the area starting from (S1)+11.
The instruction completion status is stored.
0
: Normal
Other than 0
: Error (Refer to Section 8.3 for error codes)
Specify the channel used by the host station.
1 to 8: Channel
Specify the CPU module on the station to be accessed.
Setting value
Target station CPU/control CPU/own system CPU
0000
Control CPU (The access target is the same as when "03FF
H
specified.)
03D0
6
Control system CPU
H
03D1
6
Standby system CPU
H
03D2
6
System A CPU
H
03D3
6
System B CPU
H
 Control CPU (single CPU system)
03E0
7
H
 Multiple CPU system No.1
03E1
7
Multiple CPU system No.2
H
03E2
7
Multiple CPU system No.3
H
03E3
7
Multiple CPU system No.4
H
03FF
6
Control CPU
H
When the instruction is executed with control system CPU (03D0
(03D1
) specified, if system switching occurs at the target station, the instruction execution
H
may fail. (Error code: 4244
, 4248
H
If the instruction has failed with the above error, execute it again.
Specify the network No. of the target station.
1 to 239
: Network No.
254
: Specify this when 254 has been set in Jn.
Specify the station No. of the target station.
1 to 64: Station No.
1) For instruction execution
Specify the number of times the instruction is to be resent when it is not completed within
the monitoring time specified in (S1)+8.
2) At instruction completion
The number of resends executed (result) is stored.
Setting data
b7
to
1)
0
Description
) or standby system CPU
H
)
H
MELSEC-Q
Setting range
b0
1
0001
H
0081
H
1 to 8
" is
H
0000
H
03D0
to 03D3
H
03E0
to 03E3
H
03FF
H
1 to 239
254
1 to 64
0 to 15
(Continued to the next page)
Setting
side
5
User
System
User
H
User
H
User
User
User
System
7 - 56