Mitsubishi Electric Melsec QJ71LP21 Reference Manual page 288

Q corresponding melsecnet/h network system
Hide thumbs Also See for Melsec QJ71LP21:
Table of Contents

Advertisement

7
APPLICATION FUNCTIONS
Device
Item
(S1)+6
(Use prohibited)
(S1)+7
Number of resends
Arrival monitoring
(S1)+8
time
(S1)+9
Write data length
(S1)+10 (Use prohibited)
(S1)+11 Clock set flag
(S1)+12
Clock data on error
to
completion
(S1)+15
Error-detection
(S1)+16
network No.
9
Error-detection
(S1)+17
station No.
9
5: The setting side is as shown below.
User
: It is data the user sets in the sequence program before execution of a link dedicated instruction.
System: The programmable controller CPU stores the execution result of the link dedicated instruction.
9: Data is not stored when Completion status (S1) + 1 is "Host station channel in use (F7C1
7 - 64
1) For instruction execution
Specify the number of times the instruction is to be resent when it is not completed within
the monitoring time specified in (S1)+8.
(Setting is available when the execution type is set to "1: With arrival confirmation" in
(S1)+0.)
2) At instruction completion
The number of resends executed (result) is stored.
(Setting is valid when the execution type is set to "1: With arrival confirmation" in (S1)+0.)
Specify the monitoring time required for instruction completion.
(Setting is available when the execution type is set to "1: With arrival confirmation" in
(S1)+0.)
If an instruction is not completed within this time, it will be resent the number of times
specified in (S1)+7.
0
: 10 seconds
1 to 32767 : 1 to 32767 seconds
Specify the write data size of (S2) to (S2)+n. (Refer to Section 2.2.1)
1 to 960: Number of write data (words)
Whether data stored in (S1) + 12 or later is enabled is stored.
(Data are stored when "1: Clock data at the time of error completion is set in the area
starting from (S1)+11." is set in the error completion type in (S1)+0).
Note that the stored value will not be cleared even after the dedicated instruction is
completed.
0: Invalid
1: Valid
Clock data on error completion are stored in BCD format.
(Data are stored when "1: Clock data at the time of error completion is set in the area
starting from (S1)+11." is set in the error completion type in (S1)+0).
Note that the stored value will not be cleared even after the dedicated instruction is
completed.
b15
(S1)
12
Month (01
Hour (00
(S1)
13
(S1)
14
Second (00
(S1)
15
Year (00
to 99
H
When the target station is QnACPU, "00
year).
(Clock data will not be stored when errors have been completed in the case of the ACPU.)
The network number of the station where an error has been detected is stored.
(Data are stored when "1: Clock data at the time of error completion is set in the area
starting from (S1)+11." is set in the error completion type in (S1)+0).
Note that the stored value will not be cleared even after the dedicated instruction is
completed.
1 to 239: Network No.
The station number of the station where an error has been detected is stored.
(Data are stored when "1: Clock data at the time of error completion is set in the area
starting from (S1)+11." is set in the error completion type in (S1)+0).
Note that the stored value will not be cleared even after the dedicated instruction is
completed.
1 to 64: Station No.
Setting data
to
b8
b7
to 12
)
Year (00
to 99
H
H
H
to 23
)
Date (01
H
H
Minute (00
to 59
)
H
H
), First 2 digits
Day of the week (00
H
00
(Sun.) to 06
H
" is stored in the Year field (first two digits of the
H
)".
H
Setting range Setting side
0 to 15
0 to 32767
1 to 960
to
b0
), Last 2 digits
H
to 31
)
H
H
to 59
)
H
H
to 06
)
H
H
(Sat.)
H
MELSEC-Q
5
User
System
User
User
System
System
System
System
7 - 64