APPLICATION FUNCTIONS
Control data
Device
Item
Error completion
(S1)+0
type
(S1)+1
Completion status
Channel used by
(S1)+2
host station
Target station's
(S1)+3
CPU type
Target station
(S1)+4
network No.
Target station No.
(S1)+5
5
(S1)+6
(Use prohibited)
2: The setting side is as shown below.
User
: It is data the user sets in the sequence program before execution of a link dedicated instruction.
System: The programmable controller CPU stores the execution result of the link dedicated instruction.
3: The CPU type can be specified when the host station is a network module of function version D or later.
• Network module: Serial number (first five digits) "10101" or later
(The CPU module cannot be specified in the case other than the above. Only access to the control CPU is available.)
4: The CPU type can be specified when the QCPUs and network modules of the host station or target station are the following versions.
• Network module: Serial number (first five digits) "06092" or later
• QCPU: Serial number (first five digits) "06092" or later
(The CPU module cannot be specified in the case other than the above. Only access to the control CPU is available.)
5: When a CPU in a multiple CPU system is specified for the target station CPU type ((S1)+3) and group specification (81
specified for the target station number ((S1)+5), the instruction is executed for only the system where the CPU in the multiple CPU system specified for the
target station CPU type is the control CPU of the target station.
Refer to Section 2.2.2 (5) for details.
7 - 74
b15
to
0
1) Error completion type (bit 7)
Specify the clock data setup status for error completion.
0: Clock data at the time of error completion is not set in the area starting from (S1)+11.
1: Clock data at the time of error completion is set in the area starting from (S1)+11.
The instruction completion status is stored.
0
: Normal
Other than 0 : Error (Refer to Section 8.3 for error codes)
Specify the channel used by the host station.
1 to 8: Channel
Specify the CPU module on the station to be accessed.
Setting value
Control CPU (The access target is the same as when "03FF
0000
H
specified.)
03D0
3
Control system CPU
H
03D1
3
Standby system CPU
H
03D2
3
System A CPU
H
03D3
3
System B CPU
H
 Control CPU (single CPU system)
03E0
4
H
 Multiple CPU system No.1
03E1
4
Multiple CPU system No.2
H
03E2
4
Multiple CPU system No.3
H
03E3
4
Multiple CPU system No.4
H
03FF
3
Control CPU
H
When the instruction is executed with control system CPU (03D0
(03D1
) specified, if system switching occurs at the target station, the instruction execution
H
may fail. (Error code: 4244
, 4248
H
If the instruction has failed with the above error, execute it again.
Specify the network No. of the target station.
1 to 239 : Network No.
254
: Specify this when 254 has been set in Jn.
Specify the station No. of the target station.
1) Station No. specification
1 to 64
: Station No.
2) Group specification
81
to A0
: All stations in group No.1 to 32
H
H
(Possible only for clock data write and remote RUN/STOP)
3) All stations specification
FF
: All stations of the target network No. (Except the host station)
H
(Possible only for clock write read and remote RUN/STOP)
When a group is specified, set the group No. of the target station with the network
parameters from GX Developer.
Setting data
b7
to
b4
1)
0
1
Description
) or standby system CPU
H
)
H
Setting range
to
b0
0
1
" is
H
03D0
03E0
03FF
1 to 239
1 to 64
81
(Continued to the next page)
to A0
) or all stations (FF
H
H
MELSEC-Q
Setting
side
2
0011
H
User
0091
H
System
1 to 8
User
0000
H
to 03D3
H
H
User
to 03E3
H
H
H
User
254
to A0
User
H
H
FF
H
) is
H
7 - 74