Actual value tool
The actual value tool allows to follow a synchronizing process. The display of the values
are activated by the ON button and de-activated by the OFF button. With activated
actual value tool, the setting limits ± smax and ±  Umax as well as a tracking line of the
actual value are displayed, as soon as the synchronizig process is started. To delete an
old tracking line before starting a new record, the OFF and ON buttons have to be
clicked in succession.
Transient recorder tool
Records of the three last synchronizing processes (buttons "t", "t-1" and "t-2") are stored
in the SYNCHROTACT 5 and can be displayed by the transient recorder tool. An
analogue channel records the voltage difference and three binary channels record the
paralleling command ("Channel1"), the paralleling command release ("Channel2",
SYN 5202 only) as well as the paralleling command of the device ("Command").
"Channel1" is used as trigger and ±0,5 s is recorded. On the top right, actual values in
the instant of the trigger are displayed.
Event recorder tool
The event recorder tool displays the last 256 events which are stored in the
SYNCHROTACT 5. In addition to date and time, the relative time is displayed for events
taking place during the synchronizing process. The relative time is started
simultaneously with the synchronizing process. Each event is displayed by a code and a
short text description. Further information can be displayed in a window by double click
on the text of an event.
Diagnosis tool
The diagnosis tool is a second event recorder without timestamp and with information
that has to be interpreted by the ABB development engineers. In case of "not solvable"
problems, this information can be sent to the responsible ABB office together with
parameter and event recorder data.
Since the diagnosis data has no timestamp, it should be ensured that only problem
Note
related data is sent. To achieve this, save the existing data first. Then delete it using the
Delete button, re-produce the problem, read and save data again.
Document No Art Part
Language
Revision
page
abb
3BHS109762 E01
en
D
86
ABB Switzerland Ltd
Template: CHIND Techn doc stand, A4 P de, R1.DOT; Filename: 3BHS109762E01 D.doc; Print: 12/6/2011 5:48:00 PM; Save: 12/1/2011 2:37:00 PM; CHIND No. 3BHS109763 ZAB D14 Rev. -; I-Q

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Synchrotact 5Syn 5202

Table of Contents