all mounting
During installation do not place the
inverter
with the front cover
10
facing towards the ground.
• Position the bracket
so that it is
13
perfectly level on the wall and use it
as a boring template.
• Make the 4 holes necessary, using
a drill with a 10 mm. diameter bit. The
depth of the holes must be around 70
mm.
• Secure the bracket to the wall with
the no. 4 10 mm wall plugs supplied
with it.
• Attach the inverter by inserting the
13
two tabs on the bracket
2 holes on the inverter (figure A 1 and
A2).
• Secure the inverter to the bracket
by screwing the lock screws
both sides of the inverter (figure A3).
• Unscrew the 8 screws and open
the front cover
, as described in
04
the following paragraph, to make all
necessary connections. The cover
is equipped with fixed hinges and
must not be removed. To open the
cover, follow the instructions in
the next paragraph
• Once the connections have been
made proceed to closing the cover by
tightening the 8 screws on the front,
adhering to the sequence and tighte-
ning torque (see specific paragraph
on "Closing the front cover").
04
PO W
ER
AL AR
M
GF I
into the
on
14
4 x
10 mm
Ø
ES C
UP
DO W
N
EN TE
R
A
A
A
- 45 -
5 - Installation
A
1
2
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trio-7.5-tl-outd-sTrio-8.5-tl-outd-s

Table of Contents