Setting The Operating Pressure - DURKOPP ADLER 275 Series Operating Instructions Manual

Hide thumbs Also See for 275 Series:
Table of Contents

Advertisement

Setup
Operating Instructions 275 - 02.0 - 08/2019

7.14.2 Setting the operating pressure

NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the
machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
Proper setting
Refer to the Technical data ( p. 109) chapter for the permis-
sible operating pressure. The operating pressure cannot deviate
by more than ± 0.5 bar.
Check the operating pressure on a daily basis.
Fig. 51: Setting the operating pressure
(1) - Pressure controller
To set the operating pressure:
1.
Pull the pressure controller (1) up.
2.
Turn the pressure controller until the pressure gage (2)
indicates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure controller (1) down.
(2) - Pressure gage
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents