Draining The Water Condensation - DURKOPP ADLER 275 Series Operating Instructions Manual

Hide thumbs Also See for 275 Series:
Table of Contents

Advertisement

Maintenance
Operating Instructions 275 - 02.0 - 08/2019
2.
Turn the pressure controller until the pressure gage (2)
indicates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure controller (1) down.
6.3.2

Draining the water condensation

NOTICE
Property damage from excess water!
Excess water can cause damage to the machine.
Drain water as required.
Water condensation accumulates in the water separator (2) of the
pressure controller.
Proper setting
Water condensation must not rise up to the level of the filter
element (1).
Check the water level in the water separator (2) on a daily basis.
Fig. 33: Draining the water condensation
(1) - Filter element
(2) - Water separator
To drain water condensation:
1.
Disconnect the machine from the compressed air supply.
(3) - Drain screw
71