getting started – IP setup of the Base Unit
The tool to change the IP configuration of any Base Unit will be reached via the console interface. You must
connect the Base Unit with the PC via an USB A to B cable. This will install the driver for the built in USB to
serial converter. Now you can open a terminal program. Here you must select the virtual COM port
assigned by the OS. The communication parameters are :
115200kBaud, 8, N, 1 no hand shake. Pressing <ENTER> will open the console menu :
Go for item 2 and press <ENTER> :
"Your choice: 2"
"Current network configuration
IP Address :
Netmask ... :
Gateway ... :
You must enter the IP address and the netmask.
Enter new IP address, press ENTER to cancel : "192.168.176.78"
Enter new netmask, press ENTER to cancel : "255.255.255.0"
Important Note! The gateway entry is optional but you must take care that the gateway address matches the
network mask related to the device IP address!
If you re not sure simply enter 0.0.0.0.
Enter new gateway, press ENTER to configure without gateway : "0.0.0.0"
Network configuration has been changed. Please reboot the device
To activate the new settings.
Select item 8 and press <ENTER> :
Do you want to reboot the device ?
Press small "y" :
Do you want to reboot the device ? y
Press <ENTER>
Rebooting the device ........
After reboot has finished the new IP configuration is active.
via console interface
10.110.24.128
255.255.0.0
10.110.0.1
10