junger T*AP Manual page 50

Hide thumbs Also See for T*AP:
Table of Contents

Advertisement

setup GUI – AUDIO PROCESSOR – LevelMagic™
Pls. keep in mind that the appearance of that pane depends on the respective loudness control mode (see
Input). For description of the LevelMagic™ parameters see engineering bulletin :
"LevelMagic-2_Parameters_yymmdd.pdf", which is available for download from our web site.
Link
Leveler
Loudness Target
Time (s/min/h)
Max Gain (dB)
Freeze Level (dBFS)
Transient Processor
Max Gain (dB)
Response
Limiter
Max True Peak (dBTP)
Profile (Leveler, Limiter)
Processing
defines the coupling of the control circuits (see Input)
[enable / disable] turns off Transient Processor as well.
Level mode [0 ... -50dBFS]
ITU mode
[0 ... -50LKFS]
EBU mode
[0 ... -50LUFS]
[10, 20, 40 / 1, 2, 5, 10, 20, 40 / 1, 2]
[0 ... 40]
[-20 ... -60]
[0 ... 15]
[soft, mid, hard]
[enable / disable]
[0 ... -20]
[live, speech, pop, uni, classic]
46