3.4

Set-up and assembly

3.4.1 Requirements regarding the installation site

In order to achieve sufficient safety against falls by slipping, the accessible area in the mechani-
cal machining zone of the machine must be equipped with a slip resistant mat and/or floor. The
slip resistant mat and/or the slip resistant floor must be at least R11 according to BGR 181. The
risk assessment of the machine determines whether or not this is needed.
The shoes used must be suitable for being used in those machining areas. The accessible
areas must be cleaned.
Organise the working area around the machine according to the local safety regulations.

"Work area" on page 23
The work area for operation, maintenance and repair must not be restricted.
INFORMATION
In order to attain good functionality and a high processing accuracy as well as a long service life
of the machine, the place of installation should fulfil certain criteria.
Please observe the following points:
The device must only be installed and operated in a dry and well-ventilated place.
Avoid places near machines generating chips or dust.
The installation site must be free from vibrations also at a distance of presses, planing
machines, etc.
The substructure must be suitable for the radial drilling machine. Also make sure that the
floor has sufficient load bearing capacity and is level.
The ground must be prepared in a way that potential coolants cannot penetrate the floor.
Any parts sticking out such as stops, handles, etc. have to be secured by measures taken
by the customer if necessary in order to avoid endangering persons.
Provide sufficient space for the personnel preparing and operating the machine and trans-
porting the material.
Also make sure the machine is accessible for setting and maintenance works.
Provide for sufficient backlight (Minimum value: 500 lux, measured at the tool tip). At lower
illumination intensities, additional illumination has to be ensured e.g. by means of a sepa-
rate workplace lamp.
INFORMATION
The mains plug of the radial drilling machine must be freely accessible.

3.4.2 Assembly

WARNING!
Danger of crushing and overturning.
The installation of the radial drilling machine must be performed by at least 2 persons.
3.5

Setting up RD5

WARNING!
The condition of the underground and the fixing type of the machine foot to the
underground must be in a way that it can bear the loads of the radial drilling machine.
WARNING!
First fix the machine so that it stands stable on the substructure before performing any
further installation works or disassembling the transportation locks. The foundation on