Coolant Equipment - Optimum OPTIdrill RD 5 Operating Manual

Radial drilling machine
Table of Contents

Advertisement

OPTIMUM
M A S C H I N E N - G E R M A N Y
Put the ejection wedge into the ejection opening and hit with a hammer onto the ejection
wedge. Hold the tool firmly when doing this.
Img.4-7:
Eject the drill bit or drilling chuck
4.13

Coolant equipment

WARNING!
Ejection and overflowing of coolants and lubricants. Make sure you do not get the
cooling lubricants on the floor. Cooling agents spilled on the floor must be removed
immediately.
Due to friction heat caused by the rotation movement high temperatures are generated on the
cutting edge of the tool.
Cool down the tool while drilling. In this way you attain better working results and a longer dura-
bility of the tools.
Adjust the flow using the shut-off and dosing tap.
ATTENTION!
Destruction of the pump due to dry running.
The pump is lubricated by the cooling agent. Do not operate the pump without coolant.
INFORMATION
Use a water-soluble and non-pollutant drilling emulsion as a cooling agent. This can be
acquired from authorised distributors.
Make sure that the cooling agent is being collected.
Respect the environment when disposing of lubricants and coolants.
Follow the manufacturer's disposal instructions.
GB
RD5
Page 42
Spindle sleeve
Drill drift
Spindle
Original operating instructions
Operation
Version 1.0
2017-03-13

Advertisement

Table of Contents
loading

Table of Contents