UEN00666-01
23. Remove cover (32).
24. Remove mounting bolt (33) and disconnect air
conditioner tube (34). [*1]
25. Disconnect heater hose (35).
a Check the connecting point.
26. Remove the 7 mounting bolts and air condi-
tioner unit assembly (36).
4
50 Disassembly and assembly
Installation
Installation is done in the reverse order of
q
removal.
[*1]
a When installing the air conditioner circuit hoses,
use care so that dirt, water, may not enter.
a Make sure before the installation that there is O
ring at the piping connector of the air condi-
tioner hose.
a Check that there is no defect or deterioration on
the O ring.
a When connecting the refrigerant piping, coat
the O ring with compressor oil for new refriger-
ant (R134a) (Denso: ND-OIL8, Zexcel:
ZXL100PG (PAG 46 or equivalent)).
3
Mounting bolt: 8 – 12 Nm {0.8 – 1.2 kgm}
Filling of air conditioning gas
q
By using tool X1, fill the air conditioner gas
(R134a) inside the air conditioner circuit.
a Filling quantity:850 ± 50 g
PC210, 230, 240-8