Communication Setting; Communication Parameter Settings - Mitsubishi Electric LE7-40GU Instruction Manual

Tension controller
Table of Contents

Advertisement

4.2

Communication Setting

Communication parameter settings

When using SLMP communication, set the communication parameters with the following procedure.
Setting with Data Transfer Tool
1.
Obtain the "Screen package data for SLMP communication" from your local Mitsubishi Electric representative.
2.
Transfer the "Screen package data for SLMP communication" to LE7-40GU with Data Transfer Tool (for GT Works3).
For more information on data transfer, refer to the following.
Page 14 COMMUNICATION WITH A PERSONAL COMPUTER (GT DESIGNER3, DATA TRANSFER TOOL)
3.
Select "SLMP" on the "Ethernet communication selection" screen of the LE7-40GU screen.
4.
If you want to change the IP address of LE7-40GU (default: 192.168.3.18), change it on the "IP address setting" screen
of the LE7-40GU screen.
5.
If you want to change the SLMP station No. (default: 2), change it on the "SLMP station number" screen on the LE7-
40GU screen.
6.
Restart LE7-40GU.
Precautions
For SLMP communication, only the LE7-40GU station No. and IP address can be changed on the LE7-40GU screen.
To change the port number or SLMP equipment communication settings, they must be set with GT Designer3 (GOT2000).
4 SLMP COMMUNICATION
4.2 Communication Setting
4
41