Request Code - Mitsubishi Electric LE7-40GU Instruction Manual

Tension controller
Table of Contents

Advertisement

Request code

The numerical value of each parameter corresponding to the request code is treated as real number data without a decimal
point.
In addition, the minimum and maximum values are determined for LE7-40GU, and when a value exceeding this data is
written, it is automatically rewritten to the minimum or maximum value.
In this case, an "Out of data range" alarm is generated.
Request
Name
code
H000(0)
H001(1)
Total tension
H002(2)
Left tension
H003(3)
Right tension
H004(4)
Left input voltage
H005(5)
Right input voltage
H006(6)
H007(7)
H008(8)
H009(9)
H00A(10)
H00B(11)
H00C(12)
H00D(13)
H00E(14)
H00F(15)
H010(16)
Tension upper limit detection
H011(17)
Tension lower limit detection
H012(18)
Detection outside target tension range
H013(19)
Tension display filter
H014(20)
Tension detection filter
H015(21)
Tension output filter
H016(22)
H017(23)
H018(24)
H019(25)
H01A(26)
H01B(27)
H01C(28)
H01D(29)
H01E(30)
H01F(31)
H020(32)
Sensor input type selection
H021(33)
Tension full scale
H022(34)
Tension display decimal point selection
H023(35)
Tension display unit selection
H024(36)
Span target tension
H025(37)
Left manual zero calibration
H026(38)
Right manual zero calibration
H027(39)
Left manual span calibration
H028(40)
Right manual span calibration
H029(41)
H02A(42)
H02B(43)
Monitor/
Extension
Minimum value
settings
option
Monitor
0 or less
Monitor
0 or less
Monitor
0 or less
Monitor
-1500 or less
Monitor
-1500 or less
Setting
0
Setting
0
Setting
0
Setting
5
Setting
0
Setting
0
Setting
0 (LX type), 1 (strain gauge)
Setting
1
Setting
0 (1), 1 (0.1), 2 (0.01)
Setting
0 (N), 1 (10 N)
Setting
1
Setting
-999
Setting
-999
Setting
50
Setting
50
Maximum value
Unit
2000 or more
N/10 N
2000 or more
N/10 N
2000 or more
N/10 N
1500 or more
mV
1500 or more
mV
Tension full scale
N/10 N
Tension full scale
N/10 N
50
%
80
sec
80
sec
80
sec
2000
N/10 N
Tension full scale
N/10 N
999
N/10 N
999
N/10 N
300
%
300
%
4 SLMP COMMUNICATION
4.2 Communication Setting
4
45

Hide quick links: