Link data configuration

LE7-40GU uses "1" for the number of occupied stations because the contents of the allocated link data does not change even
if the number of occupied stations of the CC-Link IE Field Network Basic slave station is changed.
*1 When using other than "1" for the number of occupied stations, all functions except remote input/output and remote register become
non-functioning.

Remote input/output

Each remote input/output has 48 points.
The remaining area becomes non-functioning and cannot be used.
• Remote output (Master Station  Slave Station)
Device No.
RY00
RY01
RY02
RY03
RY04
RY05
RY06
RY07
RY08
RY09
RY0A
RY0B
RY0C
RY0D
RY0E
RY0F
RY10
RY11
RY12
RY13
RY14
RY15
RY16
RY17
RY18
RY19
RY1A
RY1B
RY1C
RY1D
RY1E
RY1F
RY20
RY21
RY22
RY23
RY24
RY25
RY26
3 CC-LINK IE FIELD NETWORK BASIC COMMUNICATION
20
3.2 Communication Setting
Signal name
Run/Stop
Reel change B axis/A axis
Control output OFF/ON
Auto/Manual
Stall memory ON/OFF
Gain 1 ON/OFF
Gain 2 ON/OFF
Inching ON/OFF
Cutting torque ON/OFF
Constant tension ON/OFF
Predrive ON/OFF
Memory hold ON/OFF
Reverse run/Forward run
Alarm reset ON/OFF
Reel diameter reset ON/OFF
Measurement length and remaining
length reset ON/OFF
Zero adjustment execution
Span adjustment execution
Maximum diameter teaching
execution
Minimum diameter teaching
execution
Control gain tuning execution
Speed teaching execution
Data copy execution
Data initial execution
Signal name ON (data value=1)
Run
B axis control
Control output OFF
Automatic control
Stall memory ON
Gain 1 ON
Gain 2 ON
Inching ON
Cutting torque ON
Constant tension ON
Predrive ON
Memory hold ON
Reverse run operation
Alarm reset ON
Reel diameter reset ON
Measurement length and remaining length
reset ON
Execution
Execution
Start maximum diameter teaching execution
Start minimum diameter teaching execution
Start control gain tuning execution
Start speed teaching execution
Start data copy execution
Start data initial execution
OFF (data value=0)
Stop
A axis control
Control output ON
Manual control
Stall memory OFF
Gain 1 OFF
Gain 2 OFF
Inching OFF
Cutting torque OFF
Constant tension OFF
Predrive OFF
Memory hold OFF
Forward run operation
Alarm reset OFF
Reel diameter reset OFF
Measurement length and
remaining length reset OFF
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal