Link data configuration

Link data of SLMP server equipment and LE7-40GU uses D100 to D179 of SLMP equipment D device.
SLMP server equipmentLE7-40GU
Device No. (server equipment)
D100
D101
D102
D103
D104
D105
D106
D107
D108
D109
LE7-40GUSLMP server equipment
Device No. (server equipment)
Dn
Dn+1
Dn+2
Dn+3
Dn+4
Dn+5
Dn+6
Dn+7
Dn+8
Dn+9
*1 Dn switches according to the LE7-40GU SLMP station No. setting. (Station No. 1: D 110, Station No. 2: D 120 ··· Station No. 7: D 170)

Station Number command

Determine the station No. of the LE7-40GU to be accessed by the station No. command of the SLMP equipment D device (D
106).
By setting the station No. command to 0, simultaneous settings can be done for all LE7-40GU units.
Station No. command
1 to 7
0

Continuous setting/continuous monitoring

By simply turning on continuous settings execution (D103, b13) and continuous monitor execution (D103, b14) of SLMP
equipment, preset data can be set and monitored continuously.
For continuous setting data, the data set for RAM writing is not stored during a power failure.
The latest data existing in LE7-40GU when the master station gives the send request can be monitored continuously.
However, regarding the update of parameters for which the monitor update cycle is specified by the setting in LE7-40GU, the
data is updated in the specified update cycle if the specified update cycle is longer than the monitor update cycle in the send
request given by the master station.
Signal name
Station No. command
Input signal 0 to 15
Input signal 16 to 31
Input signal 32 to 47
Continuous settings 1
Continuous settings 2
Request command 0
Setting data 0
Request command 1
Setting data 1
Signal name
Output signal 0 to 15
Output signal 16 to 31
Output signal 32 to 47
Continuous monitor 1
Continuous monitor 2
Continuous monitor 3
Setting monitor 4
Request command 0 execution result
Settings command 1 execution result
Function
Individual access to designated LE7-40GU
Simultaneous access to all LE7-40GU units
Request code 0
Request code 1
4 SLMP COMMUNICATION