Mitsubishi Electric LE7-40GU Instruction Manual page 139

Tension controller
Table of Contents

Advertisement

Holding
Name
register
H10C5(4293)
Nonlinear correction 20
H10C6(4294)
Nonlinear correction 30
H10C7(4295)
Nonlinear correction 40
H10C8(4296)
Nonlinear correction 50
H10C9(4297)
Nonlinear correction 60
H10CA(4298)
Nonlinear correction 70
H10CB(4299)
Nonlinear correction 80
H10CC(4300)
Nonlinear correction 90
H10CD(4301)
H10CE(4302)
H10CF(4303)
H10D0(4304)
Powder life prediction operation selection
H10D1(4305)
Weak excitation
H10D2(4306)
Over current detection filter
H10D3(4307)
Coil limit temperature
H10D4(4308)
H10D5(4309)
H10D6(4310)
H10D7(4311)
H10D8(4312)
H10D9(4313)
H10DA(4314)
H10DB(4315)
H10DC(4316)
H10DD(4317)
H10DE(4318)
Selection of tension input
H10DF(4319)
Selection of reel diameter input
H10E0(4320)
Contact input monitor
H10E1(4321)
Contact output monitor
H10E2(4322)
General-purpose analog input 1 monitor
H10E3(4323)
General-purpose analog input 2 monitor
H10E4(4324)
General-purpose analog input 3 monitor
H10E5(4325)
General-purpose analog output 1 monitor
H10E6(4326)
General-purpose analog output 2 monitor
H10E7(4327)
Analog output monitor for TENS control
H10E8(4328)
Analog output monitor for new reel preset
H10E9(4329)
Contact input monitor for reel DIA CALC
H10EA(4330)
Contact output monitor for reel DIA CALC
H10EB(4331)
Alarm display
H10EC(4332)
Network alarm device No.
H10ED(4333)
Main unit ROM version
H10EE(4334)
Network adapter ROM version
H10EF(4335)
Communication signal monitor
H10F0(4336)
Contact input 1 function selection
H10F1(4337)
Contact input 2 function selection
H10F2(4338)
Contact input 3 function selection
H10F3(4339)
Contact input 4 function selection
H10F4(4340)
Contact input 5 function selection
H10F5(4341)
Contact input 6 function selection
H10F6(4342)
H10F7(4343)
Monitor/
Extension
Minimum value
settings
option
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0 (stop), 1 (execute)
Setting
0
Setting
0
Setting
80
Setting
0
Setting
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
LE7-DCA
0
Monitor
LE7-DCA
0
Monitor
0
Monitor
0
Monitor
0
Monitor
LE7-CCL
0
Monitor
0
Setting
0 (no function), 1 (run/stop), 2 (control
output OFF/ON), 3 (stall memory), 4
Setting
(inching ON/OFF), 5 (constant tension ON/
Setting
OFF), 6 (gain 1 ON/OFF), 7 (gain 2 ON/
OFF), 8 (automatic/manual), 9 (reel change
Setting
ON/OFF), 10 (cut torque ON/OFF), 11
Setting
(alarm reset ONOFF/OFF)
Setting
Maximum value
Unit
1000
%
1000
%
1000
%
1000
%
1000
%
1000
%
1000
%
1000
%
1000
%
20
sec
180
°C
2
2
0xFFFF
0xFFFF
100
%
100
%
100
%
100
%
100
%
100
%
100
%
0xFFFF
0xFFFF
63
999
999
999
0xFFFF
7 MODBUS/RTU, ASCII (SLAVE)
7.3 Communication Setting
7
137