Mitsubishi Electric LE7-40GU Instruction Manual page 23

Tension controller
Table of Contents

Advertisement

Device No.
RY27
RY28
RY29
RY2A
RY2B
RY2C
RY2D
RY2E
RY2F
RY30 to 3F
• Remote input (Slave Station  Master Station)
Device No.
RX00
RX01
RX02
RX03
RX04
RX05
RX06
RX07
RX08
RX09
RX0A
RX0B
RX0C
RX0D
RX0E
RX0F
RX10
RX11
RX12
RX13
RX14
RX15
RX16
RX17
RX18
RX19
RX1A
RX1B
RX1C
RX1D
RX1E
RX1F
RX20
RX21
Signal name
Link tension monitor digit 10/1
Continuous settings execution
Continuous monitor execution
Request command execution
System use area
Signal name
Run/Stop
Output ON/OFF
B-axis controlled/A-axis controlled
Constant tension ON/OFF
Predrive being executed
Memory hold being executed
Reverse running/Forward running
Manual control
Automatic control
Auto lamp flicker in operation/
stopped
Stall setting output being executed
Stall memory output being executed
Start timer operation being executed
Stop timer operation being executed
Preset timer operation being
executed
Cut torque operation being executed
Inching operation being executed
Zero adjustment being executed
Span adjustment being executed
Maximum diameter teaching being
executed
Minimum diameter teaching being
executed
Control gain tuning being executed
Speed teaching being executed
Tension upper limit detection ON/
OFF
Tension lower limit detection ON/OFF
Detection outside tension range ON/
OFF
Reel diameter detection 1 ON/OFF
Reel diameter detection 2 ON/OFF
Reel diameter detection 3 ON/OFF
Measurement length/remaining
length detection 1 ON/OFF
Measurement length/remaining
length detection 2 ON/OFF
Measurement length/remaining
length detection 3 ON/OFF
Signal name ON (data value=1)
Link tension monitor digit 10
Start continuous settings execution
Start continuous monitor execution
Start request command execution
Signal name ON (data value=1)
Run
Output ON
B-axis controlled
Constant tension ON
Predrive being executed
Memory hold being executed
Reverse running
Manual control
Automatic control
Auto lamp flicker in operation
Stall setting output being executed
Stall memory output being executed
Start timer operation being executed
Stop timer operation being executed
Preset timer operation being executed
Cut torque operation being executed
Inching operation being executed
Zero adjustment being executed
Span adjustment being executed
Speed teaching being executed
Speed teaching being executed
Control gain tuning being executed
Speed teaching being executed
Tension upper limit detection ON
Tension lower limit detection ON
Detection outside tension range ON
Reel diameter detection 1 ON
Reel diameter detection 2 ON
Reel diameter detection 3 ON
Measurement length/remaining length
detection 1 ON
Measurement length/remaining length
detection 2 ON
Measurement length/remaining length
detection 3 ON
3 CC-LINK IE FIELD NETWORK BASIC COMMUNICATION
OFF (data value=0)
Link tension monitor digit 1
Normal
Normal
Normal
OFF (data value=0)
Stop
Output OFF
A-axis controlled
Constant tension OFF
Normal
Normal
Forward running
Auto lamp flicker stopped
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Tension upper limit detection OFF
Tension lower limit detection OFF
Detection outside tension range
OFF
Reel diameter detection 1 OFF
Reel diameter detection 2 OFF
Reel diameter detection 3 OFF
Measurement length/remaining
length detection 1 OFF
Measurement length/remaining
length detection 2 OFF
Measurement length/remaining
length detection 3 OFF
3.2 Communication Setting
3
21