Mitsubishi Electric LE7-40GU Instruction Manual page 141

Tension controller
Table of Contents

Advertisement

Holding
Name
register
H1124(4388)
Menu No.
H1125(4389)
Language selection
H1126(4390)
Operation mode selection
H1127(4391)
Selection of function to use 1
H1128(4392)
Selection of function to use 2
H1129(4393)
Memory cassette backup selection
H112A(4394)
Data copy selection
H112B(4395)
Data initialization selection
H112C(4396)
H112D(4397)
H112E(4398)
H112F(4399)
H1130(4400)
Alarm history 1
H1131(4401)
Alarm history 2
H1132(4402)
Alarm history 3
H1133(4403)
Alarm history 4
H1134(4404)
Alarm history 5
H1135(4405)
Alarm history 6
H1136(4406)
Alarm history 7
H1137(4407)
Alarm history 8
H1138(4408)
Alarm history holding selection
H1139(4409)
Alarm display time
H113A(4410)
Alarm operation selection 1
H113B(4411)
Alarm operation selection 2
H113C(4412)
Alarm operation selection 3
H113D(4413)
Alarm operation selection 4
H113E(4414)
H113F(4415)
H1140(4416)
Network mode selection
H1141(4417)
Station No. in N:N Network
H1142(4418)
MODBUS station No.
H1143(4419)
MODBUS format selection
H1144(4420)
CC-Link station No.
H1145(4421)
Number of occupied stations in CC-Link
H1146(4422)
Communication speed in CC-Link
H1147(4423)
CC-Link version
H1148(4424)
Extended cyclic in CC-Link
H1149(4425)
CC-Link IE network No.
H114A(4426)
CC-Link IE station No.
H114B(4427)
H114C(4428)
H114D(4429)
H114E(4430)
H114F(4431)
Monitor/
Extension
Minimum value
settings
option
Setting
1
Setting
1 (Japanese), 2 (English), 3 (Chinese)
Setting
1 (LE7-40GU), 2 (LE-40MT), 3 (LE-30CT)
Setting
0
Setting
0
Setting
0 (backup not provided), 1 (backup
provided)
Setting
0 (No function) 1 (Copy to Menu 1), 2
(Copy to Menu 2) 3 (Copy to Menu 3) 4
(Copy to Menu 4), 5 (Copy to Menu 5), 6
(Copy to Menu 6), 7 (Copy to menu 7), 8
(Copy to Menu 8), 9 (Read from memory
cassette), 10 (write to memory cassette),
11 (Check with memory cassette)
Setting
0 (no function), 1 (initialize all parameters)
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Setting
0 (no holding), 1 (holding)
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0 (No function), 1 (N:N Network), 2
(MODBUS/RTU), 3 (MODBUS (ASCII)), 4
(CC-Link), 5 (CC-Link IEF)
Setting
1
Setting
1
Setting
0
Setting
LE7-CCL
1
Setting
LE7-CCL
0 (2 stations occupied), 1 (4 stations
occupied)
Setting
LE7-CCL
0 (156k), 1 (625k), 2 (2.5M), 3 (5M), 4
(10M)
Setting
0 (Ver.2.00), 1 (Ver.1.10)
Setting
LE7-CCL
0 (1x), 1 (2x), 2 (4x)
Setting
LE7-CCL
1
Setting
1
Maximum value
Unit
8
0xFFFF
0xFFFF
63
63
63
63
63
63
63
63
301
sec
0xFFFF
0xFFFF
0xFFFF
0xFFFF
7
247
0xFFFF
64
239
120
7 MODBUS/RTU, ASCII (SLAVE)
7.3 Communication Setting
7
139