Function code

The LE7-40GU (slave) supports the following function codes (subfunction codes).
Function code
(Subfunction code)
0x01
0x02
0x03
0x04
0x05
0x06
0x0F
0x10

Continuous setting/continuous monitoring

Data specified in advance can be set and monitored continuously by setting the continuous setting execution (RY2E) and
continuous monitor execution (RY2E) in the master station to ON.
For continuous setting data, the data set for RAM writing is not stored during a power failure.
The latest data existing in LE7-40GU when the master station gives the send request can be monitored continuously.
However, regarding the update of parameters for which the monitor update cycle is specified by the setting in LE7-40GU, the
data is updated in the specified update cycle if the specified update cycle is longer than the monitor update cycle in the send
request given by the master station.
Continuous settings
1.
Data write to devices with continuous settings 1 to 16
2.
Turn on continuous settings execution
Continuous monitor
1.
Turn on continuous monitor execution
2.
Read the data of the devices of continuous monitors 1 to 16
Function
Read Coils
Read Discrete Inputs
Read Holding Registers
Read Input Registers
Write Single Coil
Write Single Register
Write Multiple Coils
Write Multiple Register
Number of accessible device one [unit: points]
1 to 2000
1 to 2000
1 to 125
1 to 125
1
1
1 to 1968
1 to 123