Mitsubishi Electric LE7-40GU Instruction Manual page 127

Tension controller
Table of Contents

Advertisement

Request
Name
code
H02A(42)
H02B(43)
H02C(44)
H02D(45)
H02E(46)
H02F(47)
H030(48)
Reel diameter
H031(49)
Target line velocity
H032(50)
Line acceleration
H033(51)
Measurement length/remaining length
H034(52)
Reel rotational speed
H035(53)
New reel rotational speed
H036(54)
Constant slip ROTO speed command output
H037(55)
Predrive rotation speed command output
H038(56)
Predrive target rotation speed
H039(57)
Reel diameter CALC adapter ROM version
H03A(58)
H03B(59)
H03C(60)
H03D(61)
H03E(62)
H03F(63)
H040(64)
Initial diameter
H041(65)
Material thickness
H042(66)
Reel diameter detection 1
H043(67)
Reel diameter detection 2
H044(68)
Reel diameter detection 3
H045(69)
Measurement/remaining length detection 1
H046(70)
Measurement/remaining length detection 2
H047(71)
Measurement/remaining length detection 3
H048(72)
Accelerating judgment acceleration
H049(73)
Reel rotational speed gain
H04A(74)
Reel rotational speed bias
H04B(75)
Reel rotational speed startup gain
H04C(76)
Reel rotational speed startup timer
H04D(77)
Predrive time
H04E(78)
Predrive bias
H04F(79)
H050(80)
Maximum diameter
H051(81)
Minimum diameter
H052(82)
Teaching speed
H053(83)
Velocity electronic gear ratio
H054(84)
Reel selection
H055(85)
Number of reel pulse
H056(86)
Reel diameter calculation cycle
H057(87)
MEAS/RMN length calculation switch
H058(88)
Material thickness unit
H059(89)
Maximum line acceleration
H05A(90)
Maximum reel rotational speed
Monitor/
Extension
Minimum value
settings
option
Monitor
1
Monitor
LE7-DCA
0
Monitor
LE7-DCA
0
Monitor
LE7-DCA
Monitor
LE7-DCA
65000
Monitor
LE7-DCA
3600
Monitor
LE7-DCA
1000
Monitor
LE7-DCA
1000
Monitor
LE7-DCA
3600
Monitor
LE7-DCA
999
Setting
LE7-DCA
1
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
1
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
-10
Setting
Minimum diameter
Setting
1
Setting
LE7-DCA
1
Setting
LE7-DCA
9000
Setting
LE7-DCA
0(unwinding), 1(winding)
Setting
LE7-DCA
0 (1 pulse), 1 (2 pulses), 2 (4 pulses), 3 (8
pulses), 4 (16 pulses)
Setting
LE7-DCA
0 (1 pulse), 1 (2 pulses), 2 (4 pulses), 3 (8
pulses), 4 (16 pulses)
Setting
LE7-DCA
0 (measurement length), 1 (remaining
length)
Setting
LE7-DCA
0 (1), 1 (0.1)
Setting
LE7-DCA
1
Setting
LE7-DCA
1
Maximum value
Unit
2000
mm
10000
m/min
50
m/min/sec
m
1
r/min
1
r/min
0.1
%
0.1
%
1
r/min
0.01
2000
mm
10000
μm
2000
mm
2000
mm
2000
mm
65000
m
65000
m
65000
m
10
m/min/sec
150
%
100
%
5
Time (s)
10
sec
200
sec
10
%
2000
mm
Maximum diameter
mm
10000
m/min
18000
%
50
m/min/sec
3600
r/min
7 MODBUS/RTU, ASCII (SLAVE)
7.3 Communication Setting
7
125

Hide quick links: