Mitsubishi Electric LE7-40GU Instruction Manual page 138

Tension controller
Table of Contents

Advertisement

Holding
Name
register
H1095(4245)
Broken line taper ratio 3
H1096(4246)
Broken line taper corner 4
H1097(4247)
Broken line taper ratio 4
H1098(4248)
Broken line taper corner 5
H1099(4249)
Broken line taper ratio 5
H109A(4250)
Broken line taper corner 6
H109B(4251)
Broken line taper ratio 6
H109C(4252)
Broken line taper corner 7
H109D(4253)
Broken line taper ratio 7
H109E (4254)
Broken line taper corner 8
H109F(4255)
Broken line taper ratio 8
H10A0(4256)
Proportional gain
H10A1(4257)
Integral time
H10A2(4258)
Dead band gain
H10A3(4259)
Dead band width
H10A4(4260)
Tension control filter
H10A5(4261)
Static mechanical loss A
H10A6(4262)
Static mechanical loss B
H10A7(4263)
Kinetic mechanical loss A
H10A8(4264)
Kinetic mechanical loss B
H10A9(4265)
Mass correction gain A
H10AA(4266)
Mass correction gain B
H10AB(4267)
Mass correction bias A
H10AC(4268)
Mass correction bias B
H10AD(4269)
H10AE(4270)
H10AF(4271)
H10B0(4272)
Control mode selection
H10B1(4273)
Integral feedback limit
H10B2(4274)
Feedback selection during the stop timer
H10B3(4275)
Automatic control output polarity selection
H10B4(4276)
Open-loop control ratio
H10B5(4277)
Taper function selection
H10B6(4278)
Selection of two reel's switching FUNC
H10B7(4279)
Internal taper standard selection
H10B8(4280)
H10B9(4281)
Mechanical loss function selection
H10BA(4282)
Stall automatic calculation gain
H10BB(4283)
New reel preset AUTO calculation gain
H10BC(4284)
Control output upper limit
H10BD(4285)
Control output lower limit
H10BE(4286)
H10BF(4287)
H10C0(4288)
Load model
H10C1(4289)
Rated current
H10C2(4290)
Maximum torque correction
H10C3(4291)
Nonlinear correction 0
H10C4(4292)
Nonlinear correction 10
7 MODBUS/RTU, ASCII (SLAVE)
136
7.3 Communication Setting
Monitor/
Extension
Minimum value
settings
option
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
-1000
Setting
-1000
Setting
LE7-DCA
-1000
Setting
LE7-DCA
-1000
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0 (feedback control), 1 (open loop control)
Setting
0
Setting
0 (invalid), 1 (valid)
Setting
0 (forward), 1 (reverse)
Setting
LE7-DCA
0
Setting
0 (no function), 1 (internal taper), 2 (linear
line taper (external)), 3 (broken line taper
(external)), 4 (direct taper)
Setting
0 (invalid), 1 (valid)
Setting
0 (zero standard), 1 (stall standard)
Setting
LE7-DCA
0 (fixed mechanical loss), 1 (high function
mechanical loss)
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
Control output lower
limit
Setting
-101
Setting
0
Setting
0
Setting
50
Setting
0
Setting
0
Maximum value
Unit
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
100
%
100
%
100 - Proportional
%
gain
100
%
40
sec
1000
%
1000
%
1000
%
1000
%
100
%
100
%
100
%
100
%
101
%
100
%
100
%
100
%
101
%
Control output
%
upper limit
200
400
A
250
%
1000
%
1000
%