Mitsubishi Electric LE7-40GU Instruction Manual page 31

Tension controller
Table of Contents

Advertisement

Request
Name
code
H0EB(235)
Alarm display
H0EC(236)
Network alarm device No.
H0ED(237)
Main unit ROM version
H0EE(238)
Network adapter ROM version
H0EF(239)
Communication signal monitor
H0F0(240)
Contact input 1 function selection
H0F1(241)
Contact input 2 function selection
H0F2(242)
Contact input 3 function selection
H0F3(243)
Contact input 4 function selection
H0F4(244)
Contact input 5 function selection
H0F5(245)
Contact input 6 function selection
H0F6(246)
H0F7(247)
H0F8(248)
Contact output 1 function selection
H0F9(249)
Contact output 2 function selection
H0FA(250)
H0FB(251)
H0FC(252)
H0FD(253)
H0FE(254)
H0FF(255)
H100(256)
Analog input mode selection
H101(257)
Analog input 1 function selection
H102(258)
Analog input 2 function selection
H103(259)
Analog input 3 function selection
H104(260)
H105(261)
H106(262)
H107(263)
H108(264)
Analog output mode selection
H109(265)
Analog output 1 function selection
H10A(266)
Analog output 2 function selection
H10B(267)
Analog output 1 gain
H10C(268)
Analog output 2 gain
H10D(269)
Analog output 1 bias
H10E(270)
Analog output 2 bias
H10F(271)
H110(272)
Two reel's switching FUNC output mode
H111(273)
Control output mode selection
H112(274)
Control output gain
H113(275)
New reel preset output gain
H114(276)
Control output bias
H115(277)
New reel preset output bias
H116(278)
Monitor/
Extension
Minimum value
settings
option
Monitor
0
Monitor
0
Monitor
0
Monitor
LE7-CCL
0
Monitor
0
Setting
0 (no function), 1 (run/stop), 2 (control
output OFF/ON), 3 (stall memory), 4
Setting
(inching ON/OFF), 5 (constant tension ON/
Setting
OFF), 6 (gain 1 ON/OFF), 7 (gain 2 ON/
OFF), 8 (automatic/manual), 9 (reel change
Setting
ON/OFF), 10 (cut torque ON/OFF), 11
Setting
(alarm reset ON/OFF)
Setting
Setting
0 (no function), 1 (tension lower limit
detection), 2 (tension upper limit detection),
Setting
3 (detection outside tension range), 4
(alarm occurrence detection)
Setting
0 (0 to 5 V mode), 1 (0 to 10 V mode)
Setting
0 (no function), 1 (tension setting), 2 (stall
setting), 3 (straight line taper ratio setting),
Setting
4 (new axis preset setting), 5 (manual
Setting
setting), 6 (tension input), 7 (Reel diameter
input)
Setting
0 (0 to 5 V mode), 1 (0 to 10 V mode)
Setting
0 (no function), 1 (tension monitor), 2 (Reel
diameter monitor), 3 (tension setting
Setting
monitor), 4 (A-axis Reel shaft rotational
speed output), 5 (B-axis Reel shaft
rotational speed output)
Setting
500
Setting
500
Setting
-500
Setting
-500
Setting
0 (no internal switching), 1 (with internal
switching)
Setting
0 (0 to 5 V mode), 1 (-5 to 5 V mode), 2 (0
to 10 V mode), 3 (-10 to 10 V mode), 4 (0 to
8 V mode), 5 (- 8 to 8 V mode), 6 (0 to 2.7 V
mode), 7 (-2.7 to 2.7 V mode), 8 (1 to 5 V
mode)
Setting
500
Setting
500
Setting
-500
Setting
-500
3 CC-LINK IE FIELD NETWORK BASIC COMMUNICATION
Maximum value
Unit
63
999
999
999
0xFFFF
3000
%
3000
%
500
%
500
%
3000
%
3000
%
500
%
500
%
3.2 Communication Setting