Mitsubishi Electric LE7-40GU Instruction Manual page 135

Tension controller
Table of Contents

Advertisement

• Configuration of holding register (for slave station RAM+ROM writing)
The configuration of the holding register is as follows.
Holding
Name
register
H1000(4096)
H1001(4097)
Total tension
H1002(4098)
Left tension
H1003(4099)
Right tension
H1004(4100)
Left input voltage
H1005(4101)
Right input voltage
H1006(4102)
H1007(4103)
H1008(4104)
H1009(4105)
H100A(4106)
H100B(4107)
H100C(4108)
H100D(4109)
H100E(4110)
H100F(4111)
H1010(4112)
Tension upper limit detection
H1011(4113)
Tension lower limit detection
H1012(4114)
Detection outside target tension range
H1013(4115)
Tension display filter
H1014(4116)
Tension detection filter
H1015(4117)
Tension output filter
H1016(4118)
H1017(4119)
H1018(4120)
H1019(4121)
H101A(4122)
H101B(4123)
H101C(4124)
H101D(4125)
H101E(4126)
H101F(4127)
Tension input filter
H1020(4128)
Sensor input type selection
H1021(4129)
Tension full scale
H1022(4130)
Tension display decimal point selection
H1023(4131)
Tension display unit selection
H1024(4132)
Span target tension
H1025(4133)
Left manual zero calibration
H1026(4134)
Right manual zero calibration
H1027(4135)
Left manual span calibration
H1028(4136)
Right manual span calibration
H1029(4137)
H102A(4138)
Tension full scale10 data
H102B(4139)
Span adjustment data range switching
H102C(4140)
Left zero adjustment data
H102D(4141)
Right zero adjustment data
H102E(4142)
Left span adjustment data
H102F(4143)
Right span adjustment data
H1030(4144)
Reel diameter
H1031(4145)
Target line velocity
Monitor/
Extension
Minimum value
settings
option
Monitor
0 or less
Monitor
0 or less
Monitor
0 or less
Monitor
-1500 or less
Monitor
-1500 or less
Setting
0
Setting
0
Setting
0
Setting
5
Setting
0
Setting
0
Setting
50
Setting
0 (LX type), 1 (strain gauge)
Setting
1
Setting
0 (1), 1 (0.1), 2 (0.01)
Setting
0 (N), 1 (10 N)
Setting
1
Setting
-999
Setting
-999
Setting
50
Setting
50
Setting
10
Monitor
0
Monitor
-32768
Monitor
-32768
Setting
-32768
Setting
-32768
Monitor
1
Monitor
LE7-DCA
0
Maximum value
Unit
2000 or more
N/10 N
2000 or more
N/10 N
2000 or more
N/10 N
1500 or more
mV
1500 or more
mV
Tension full scale
N/10 N
Tension full scale
N/10 N
50
%
80
sec
80
sec
80
sec
200
2000
N/10 N
Tension full scale
N/10 N
999
N/10 N
999
N/10 N
300
%
300
%
20000
15
32767
32767
32767
32767
2000
mm
10000
m/min
7 MODBUS/RTU, ASCII (SLAVE)
7.3 Communication Setting
7
133