Ladder Operation
Operation is changed depending on the sequence No. When the PLC is started, the sequence No. 1 is set, and the station
No. command is changed as the following table (station No. 1). When the station No. response (station No. 2) and the station
No. response (station No. 3) match with the station No. command, the sequence No. increases by one. When the process up
to sequence No. 3 is complete, the number returns to 0.
Sequence No.
Station No.
(D20)
command
(D100)
0
1
1
2
2
1
3
3
Using method of ladder
List of used devices (The allocation is an example.)
Device name
Station No. 2 Station No. 3
D200 to D203
D210 to D213
D204 to D205
D214 to D215
D300 to D303
D310 to D313
D400 to D401
D410 to D413
X20
X30
X21
X31
X22
X32
X23
X33
X24
X34
Y30
Y40
Y31
Y41
Y32
Y42
Y33
Y43
Y34
Y44
Y35
Y45
Y36
Y46
D100 to D109
D110 to D119
D120 to D129
D20
M100
D10
D11
*1 Classification
Setting: items to be set/input when using functions
Monitoring: items to monitor output when using functions
System: Used for internal processing, setting is unnecessary
4 SLMP COMMUNICATION
60
4.3 Reference Program
Station No.
Station No.
offset (D10)
command
being
changed
(M100)
2
OFF
2
ON
3
OFF
3
ON
*1
Classification
Allocation function
Setting
Request command + request code/data
setting 1 to 2
Setting
Request command execution result 1 to 2
Setting
Continuous monitor 1 to 4
Setting
Continuous setting 1 to 2
Setting
Start request command access execution
Setting
Start continuous monitor execution
Setting
Start continuous setting execution
Setting
Start stall execution
Monitoring
Start operation
Monitoring
Run
Monitoring
Manual control
Monitoring
Automatic control
Monitoring
Auto lamp flicker in operation
Monitoring
Request command completion
Monitoring
Continuous monitor being executed
Monitoring
Continuous settings being executed
System
Link data (Station No. 1)
System
Link data (Station No. 2)
System
Link data (Station No. 3)
System
Sequence No.
System
Station No. command being changed
System
Station No. command storage device
System
Station No. offset
Available
Description
Setting
Monitoring
Change the setting value of station No. 2.
Change the station No. command to 2. Setting
value is reflected.
Change the setting value of station No. 3.
Change the station No. command to 3. Setting
value is reflected.
Use
Device set to use the request command
Request command execution result is stored.
Continuous monitor execution result is stored.
Setting value of continuous setting is stored.
Execute request command.
Start to execute continuous monitor.
Start to execute continuous setting.
Start to execute stall.
Start to operate.
Run: ON/Stop: OFF
Manual control ON
Automatic control ON
Auto lamp flicker in operation ON
ON when request command is completed
ON when continuous monitor is being executed.
ON when continuous setting is being executed.
Setting items such as input signal are stored.
Monitored item from station No. 2 is stored.
Monitored item from station No. 3 is stored.
Processing is changed by the sequence No.
Turn ON when the station No. command is being
written.
Offset the device according to the station No.
Used to offset the device