Mitsubishi Electric LE7-40GU Instruction Manual page 29

Tension controller
Table of Contents

Advertisement

Request
Name
code
H087(135)
Acceleration/deceleration torque setting
H088(136)
Gain 1
H089(137)
Gain 2
H08A(138)
Internal taper ratio
H08B(139)
External linear line taper ratio
H08C(140)
New reel preset
H08D(141)
New reel preset timer
H08E(142)
Cutting torque
H08F(143)
H090(144)
Broken line taper corner 1
H091(145)
Broken line taper ratio 1
H092(146)
Broken line taper corner 2
H093(147)
Broken line taper ratio 2
H094(148)
Broken line taper corner 3
H095(149)
Broken line taper ratio 3
H096(150)
Broken line taper corner 4
H097(151)
Broken line taper ratio 4
H098(152)
Broken line taper corner 5
H099(153)
Broken line taper ratio 5
H09A(154)
Broken line taper corner 6
H09B(155)
Broken line taper ratio 6
H09C(156)
Broken line taper corner 7
H09D(157)
Broken line taper ratio 7
H09E(158)
Broken line taper corner 8
H09F(159)
Broken line taper ratio 8
H0A0(160)
Proportional gain
H0A1(161)
Integral time
H0A2(162)
Dead band gain
H0A3(163)
Dead band width
H0A4(164)
Tension control filter
H0A5(165)
Static mechanical loss A
H0A6(166)
Static mechanical loss B
H0A7(167)
Kinetic mechanical loss A
H0A8(168)
Kinetic mechanical loss B
H0A9(169)
Mass correction gain A
H0AA(170)
Mass correction gain B
H0AB(171)
Mass correction bias A
H0AC(172)
Mass correction bias B
H0AD(173)
H0AE(174)
H0AF(175)
H0B0(176)
Control mode selection
H0B1(177)
Integral feedback limit
H0B2(178)
Feedback selection during the stop timer
H0B3(179)
Automatic control output polarity selection
H0B4(180)
Open-loop control ratio
H0B5(181)
Taper function selection
H0B6(182)
Selection of two reel's switching FUNC
H0B7(183)
Internal taper standard selection
H0B8(184)
Monitor/
Extension
Minimum value
settings
option
Setting
LE7-DCA
0
Setting
5
Setting
5
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
1
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
-1000
Setting
-1000
Setting
LE7-DCA
-1000
Setting
LE7-DCA
-1000
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0
Setting
LE7-DCA
0 (feedback control), 1 (open loop control)
Setting
0
Setting
0 (invalid), 1 (valid)
Setting
0 (forward), 1 (reverse)
Setting
LE7-DCA
0
Setting
0 (no function), 1 (internal taper), 2 (linear
line taper (external)), 3 (broken line taper
(external)), 4 (direct taper)
Setting
0 (invalid), 1 (valid)
Setting
0 (zero standard), 1 (stall standard)
3 CC-LINK IE FIELD NETWORK BASIC COMMUNICATION
Maximum value
Unit
1000
%
400
%
400
%
80
%
100
%
1000
%
300
sec
1000
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
2000
mm
100
%
100
%
100
%
100 - Proportional
%
gain
100
%
40
sec
1000
%
1000
%
1000
%
1000
%
100
%
100
%
100
%
100
%
101
%
100
%
3.2 Communication Setting
3
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents