AutoGRAPH- ST – Remote Control Command
SECURESETUP
Command
Name
Supported with firmware
Description
Commands format:
password SECURESETUP=status,password;
parameters of the commands:
status – specify following value:
0 – to disable the protection;
1 – to enable the protection;
password – protection password which will be set in the device. The password can be
exactly four characters long and have only digits from 0 to 9.
Reply format:
#SECURESETUP=sec,status;
parameters of the reply:
sec – current state of the device protection:
0 – protection is disabled;
1 – protection is enabled.
status – the command processing state:
0 – an error occurred while processing the command. It is recommended to check the
command format and password specified in the command.
1 – the command is processed successfully.
44
SECURESETUP
Device password activation
AGST-0.75 and higher
Command is intended to disable the device settings
protection. If the protection is enabled it will be
unavailable to change the settings by means of the
AGSTConf Software without entering the security
password. The configuration via SMS always requires
the device password.