AutoGRAPH- ST – Remote Control Command
SERVERPERIOD
Command
Name
Supported with firmware
Description
Command format:
password SERVERPERIOD=hours,minutes,type;
parameters of the command:
hours,minutes – a period or exact time of data transmission to server. Minimum value
is 10 sec, maximum – 168 hours (1 week).
type – mode of data transmission:
0 – enables periodical data transmission with the specified period;
1 – enables everyday data transmission at the scheduled time.
Sample command:
5672 SERVERPERIOD=15,30,1;
Sample reply:
#SERVERPERIOD=15,30,1;
The device is set up to the data every day at 15:30.
Note:
Parameter "type" is available for AutoGRAPH-ST devices with firmware of
version AGST-0.81 and higher. For the previous versions of firmware, use
following format of the command:
These devices support only periodical data transmission.
22
SERVERPERIOD
Data transmission period
AGST-0.75 and higher
Command is intended to specify a period of data
transmission to server. This command is used to specify
both the period of data transmission and the exact time
of data transmission. In last case the device won‟t
transfer data periodically, but every day at scheduled
time.
"SERVERPERIOD=hours,minutes;".