Omron Viper 650 User Manual page 80

Robot with emb-60r
Hide thumbs Also See for Viper 650:
Table of Contents

Advertisement

5.9  Installing User-Supplied Safety Equipment
Table 5-8. Contacts Provided by the XUSR Connector
Pin
Description
Pairs
Voltage-Free Contacts Provided by Customer
1, 14
User E-Stop CH 1 (mushroom push-
button, safety gates, etc.)
2, 15
User E-Stop CH 2 (same as pins
1, 14)
3, 16
Line E-Stop (used for other robot or
assembly line E-Stop inter-
connection. Does not affect E-Stop
indication (pins 7, 20))
4, 17
Line E-Stop (same as pins 3, 16)
5, 18
Muted safety gate CH 1 (causes E-
Stop in Automatic mode only)
Muted Safety Gate CH 2 (same
6, 19
as pins 5, 18)
Voltage-Free Contacts provided by Viper
E-Stop indication CH 1
7, 20
E-Stop indication CH 2 (same as
8, 21
pins 7, 20)
Manual/Automatic indication CH
9, 22
1
Manual/Automatic indication CH
10, 23
2
No connection
11, 12,
13, 24,
25
80
Comments
N/C contacts, Shorted if NOT Used
N/C contacts, Shorted if NOT Used
N/C contacts, Shorted if NOT Used
N/C contacts, Shorted if NOT Used
N/C contacts, Shorted if NOT Used
N/C contacts, Shorted if NOT Used
Contacts are closed when Front Panel,
pendant, and customer E-Stops are not
tripped
Contacts are closed when Front Panel,
pendant, and customer E-Stops are not
tripped
Contacts are closed in Automatic mode
Contacts are closed in Automatic mode
Viper 650/850 Robot with eMB-40/60R User's Guide