Objects "Threshold; Objects "Blinds - HDL M/R4.16.1 Manual

Knx/eib bus
Table of Contents

Advertisement

HDL KNX / EIB

4.2.11 Objects "Threshold"

NO.
Object name
Output N
21
If this communication object is actived , the threshold input value from bus compare with
threshold 1 and threshold 2, and calculate the status of switch according to the setting of
database.
Output N
22
Change threshold1 value via bus.
Output N
23
Change threshold2 value via bus.
Table 15 Threshold

4.2.12 Objects "Blinds"

NO.
Object name
Output N
24
This communication object control blinds move UP/DOWN. The blinds move UP/DOWN
run or stop by the value of receiving telegram from the bus or stop until timeout .
Output N
25
This communication object control blinds adjust or stop.
receiving '1' or '0' for stop moving.Otherwise adjust the blinds.
Table 16 Blinds
_____________________________________________________________________________________
Guangzhou Hedong Electronic Co.,Ltd (HDL)
Function
Threshold input
Change threshold
1
Change threshold
2
Function
Moving for
Blinds(0-UP,1-DOWN)
Adjust/Stop for Blinds
Switch Actuators
Flags
C W U
C W U
C W U
Flags
C W U
C W U
the blinds moving,Then
If
www.hdlchina.com
Data type
EIS14
DPT 5.004 1byte
EIS10
DPT 7.001 2bytes
EIS14
DPT 5.004 1byte
EIS10
DPT 7.001 2bytes
EIS14
DPT 5.004 1byte
EIS10
DPT 7.001 2bytes
Data type
EIS1
DPT 1.008
1bit
EIS1
DPT 1.007
1bit
47/58