HDL KNX / EIB
Staircase light
4.2.7 Objects "
NO.
Object name
Output N
17
This communication object is used for start or stop staircase light
Table 11 Staircase light

4.2.8 Objects"Change staircase lighting time"

NO.
Object name
Output N
18
This communication object is used to modify the staircase lighting running time. allow
modify staircase lighting time via bus by setting this function activity.
Table 12 Change staircase light running time(2byte)

4.2.9 Objects "Alarm staircase lighting"

NO.
Object name
Output N
19
This communication object is used to alarm the staircase lighting. If the function is
actived, the staircase lighting start or stop ,the communication object will alarm via bus.
channel "N" is ON alarm "1", Otherwise alarm "0'.
Table 13 Alarm staircase light
_____________________________________________________________________________________
Guangzhou Hedong Electronic Co.,Ltd (HDL)
"
Function
Staircase light
Function
Change staircase
lighting time
Function
Alarm staircase
lighting
Switch Actuators
Flags
C W U
Flags
C W U
Flags
C R T
www.hdlchina.com
Data type
EIS1
DPT 1.001
1bit
Data type
EIS10
DPT 7.005
2byte
Data type
EIS1
DPT 1.005
1bit
45/58