Mixed Panel Bus I/O Module Cliop830A - Honeywell CENTRA LINE LION CLLIONLC01 Installation & Commissioning Instructions

Table of Contents

Advertisement

Description of the I/O Modules

Mixed Panel Bus I/O Module CLIOP830A

Features
• Type: CLIOP830A Mixed Panel Bus I/O Module
• Housing: light-gray
In the event of communication problems, the relay outputs
will move to the safety positions you have configured using
the engineering tool, see relay output point description in the
CARE – User Guide, EN2B-0182GE51 / 74-5587.
71
COM a
72
COM b
73
24V~
74
24V~0
Binary Inputs
B7
B8 B9 B10 B11 B12
7
8
9
10 11 12
1
2
3
4
5
B1 B2 B3 B4 B5 B6
1 2 3 4 5 6 7 8 9 10 11 12
Install. Instr.
DI
EN1B-0375GE51
CLIOP830A
12 BI / 8 AI / 8 AO / 6 RO
7 8 9 10 11 12 17 18 19 20
24V, 15VA, T50
0706AX0001-XFU830A
8
Made in Germany
0532
1
2 3 4 5 6 13 14 15 16
A
A1 A2 A3 A4 A5 A6 A7 A8 A9
B1 B2 B3 B4 B5 B6 B7 B8 B9
C
A1 A2 A3 A4 A5 A6 A7 A8 A9
B1 B2 B3 B4 B5 B6 B7 B8 B9
Fig. 85
CLIOP830A Mixed I/O Module (shown with aux.
terminal packages)
71
COM a
72
COM b
73
24V~
74
24V~0
Binary Inputs
B7
B8 B9 B10 B11 B12
7
8
9
10 11 12
5
1
2
3
4
B1 B2 B3 B4 B5 B6
1 2 3 4 5 6 7 8 9 10 11 12
Install. Instr.
DI
EN1B-0375GE51
CLIOP830A
12 BI / 8 AI / 8 AO / 6 RO
7 8 9 10 11 12 17 18 19 20
24V, 15VA, T50
0706AX0001-XFU830A
8
Made in Germany
0532
1
2 3 4 5 6 13 14 15 16
Fig. 86
CLIOP830A Mixed I/O Module - features
Legend
1
Hex switch S2
2
Status LEDs
3
Service LED
4
Power LED
Functionality of service LED and power LED: see Table 77
to Table 79 on page 78.
EN1Z-0921GE51 R0709
COM a
External
40
24V
COM b
4
24V for relay 1...5
24V~0
S2
J1
J2
J3
J4
J5
Analog Inputs
Analog Outputs
24V Relays
GND
AO5
AO6 AO7 AO8 IN1 IN2 IN3 IN4 IN5 IN6
AI5
AI6 AI7 AI8
17
18 19 20
25
26 27 28
35
36 37 38 39 40
6
13 14 15 16
G1 G2
21 22 23 24
29 30 31 32 33 34
AI1 AI2 AI3 AI4
41
42
AO1 AO2 AO3 AO4 NO1 NO2 NO3 NO4 NO5 NO6
1 2 3 4 5 6
25 26 27 28 35 36 37 38 39 40
41 42
21 22 23 24 29 30 31 32 33 34
B
A1 A2 A3 A4 A5 A6 A7 A8 A9
B1 B2 B3 B4 B5 B6 B7 B8 B9
D
A1 B1 A2 B2 A3 B3 A4 B4 G1
A5 B5 A6 B6 A7 B7 A8 B8
1
COM a
External
40
24V
COM b
4
24V for relay 1...5
24V~0
S2
J1
J2
J3
J4
J5
Analog Inputs
Analog Outputs
24V Relays
GND
AI5
AI6 AI7 AI8
AO5
AO6 AO7 AO8 IN1 IN2 IN3 IN4 IN5 IN6
17
18 19 20
25
26 27 28
35
36 37 38 39 40
6
13 14 15 16
G1 G2
21 22 23 24
29 30 31 32 33 34
AI1 AI2 AI3 AI4
41
42
AO1 AO2 AO3 AO4 NO1 NO2 NO3 NO4 NO5 NO6
1 2 3 4 5 6
25 26 27 28 35 36 37 38 39 40
41 42
21 22 23 24 29 30 31 32 33 34
2
WARNING
Risk of electric shock or equipment damage!
It is not permitted to wire the relays of the mixed Panel
Bus I/O modules for anything other than low voltage.
Permissible Loads
75
76
24V~
77
78
per mixed
Panel Bus I/O
module (total
for all relay
!
contacts)
DO
per normally
open contact
G2
Table 60 Permissible loads of mixed Panel Bus I/O
75
76
24V~
77
78
!
DO
3
4
62
load
24 VDC/VAC
max. 3 A resistive or induc-
tive, cos φ ≥ 0.6,
no capacitive load
24 VDC/VAC
min. 0.05 A resistive or
inductive, cos φ ≥ 0.6,
max. 0.5 A resistive or
inductive, cos φ ≥ 0.6,
no capacitive load
modules
LION System
min. load
>50 mW

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents